An Inline-Integrable Image Restoration Model With ROI Fine-Tuning and Slice-to-Volume Reconstruction for Accelerated Whole-Brain Vessel Wall Imaging.
Pengcheng Wang, Jingxiang Zhang, Jiayu Xiao, Junzhou Chen, Zhenjia Wang, Jin Li, Qingle Kong, Steven Y Cen,
Department of Radiology, University of Southern California, Los Angeles, California, USA. · Department of Radiology, Anzhen Hospital, Beijing, China.
Key points
From the paper's conclusion- The proposed inline-integrable image restoration model enables clinically viable whole-brain VWI in under 6 min using standard 20-channel coils, offering a practical approach to improve patient throughput without compromising diagnostic quality.
Abstract
PURPOSE: To develop a vessel wall imaging (VWI)-dedicated image restoration model enabling high-resolution whole-brain VWI in under 6 min. METHODS: A transformer-based 2.5D model was trained in a supervised manner to enhance the image quality of CAIPIRINHA 2 × 2-accelerated VWI acquisitions to a level comparable to that of GRAPPA twofold-accelerated scans. The majority of k-space data used for training and testing were acquired on a Siemens 3 T system equipped with a standard 20-channel head-neck coil. Region-of-interest fine-tuning and slice-to-volume reconstruction were devised to balance global structural fidelity with local vascular precision and 3D continuity. Model performance was evaluated both quantitatively and qualitatively through single-center retrospective testing and prospective testing in multi-center, generalized settings. Integration of the model into the vendor's inline image reconstruction pipeline was also investigated. RESULTS: Compared with the input images, model outputs improved peak SNR by more than 7 dB and structural similarity index measure by 0.19 in the retrospective test set. When applied to CAIPIRINHA fourfold-accelerated data that otherwise underwent offline or inline GRAPPA reconstruction, the model significantly enhanced vessel wall SNR, wall-to-lumen CNR, wall-to-cerebrospinal fluid CNR, and image quality scores. These improvements were sustained in an independent cohort from different institutions and reproduced in a dataset acquired with smaller field of view and a 64-channel coil, supporting the model's robustness and generalizability. CONCLUSION: The proposed inline-integrable image restoration model enables clinically viable whole-brain VWI in under 6 min using standard 20-channel coils, offering a practical approach to improve patient throughput without compromising diagnostic quality.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Highly Accelerating Joint Intracranial and Carotid Vessel Wall Imaging Using ESPIRiT-Driven Diffusion Model Reconstruction.Magnetic resonance in medicine · 2026
- Deep Learning-Accelerated 3D Vessel Wall MRI: Prospective Evaluation of Sonic DL with Substantial Scan Time Reduction.AJNR. American journal of neuroradiology · 2026
- Automated Brain Segmentation in Accelerated T2-Weighted MRI: Effects of Deep Learning-Based ReconstructionmedRxiv · 2026
- Deep Learning Reconstruction for Accelerated Radial CEST MR Fingerprinting.ArXiv · 2026
- Spectrally optimized implicit neural representations mitigate acquisition-related image quality trade-offs in intracranial 4D Flow MRIarXiv · 2026
- Enabling Highly Accelerated Multi-shot IVIM-DWI with a Data-sharing-guided Framework: Joint Image Reconstruction and Biomarker Estimation.NeuroImage · 2026