科研速览 · Science Skim继续刷下去 · Keep skimming →
◆ Magnetic resonance in medicine2026-08-17

Multi-Vendor and Multi-Site Characterization of 13C Coils for Clinical Studies.

Emil S Christensen, Andreas Clemmensen, Esben S S Hansen, Jonathan Birchall, Mary A McLean, Christoffer Laustsen, Andreas Kjaer, Thomas L Andersen

一句话结论 · In one sentence

This standardization aims to strengthen multi-center trials by ensuring data comparability and reliability, advancing the clinical translation of 13C MRS methodologies. The results and analysis pipeline is made publicly available to facilitate implementation and coil comparisons across institutions.

原始摘要(英文原文)· Original abstract
PURPOSE: Due to the inherently low signal-to-noise ratio (SNR) domain for 13C imaging, optimal coil performance is essential to maximize data quality. Quality control (QC) for 13C coils employed in magnetic resonance spectroscopy (MRS) is of paramount importance. This study presents a gradient-recalled echo (GRE) sequence alongside an image-based analysis for SNR estimation and QC of 13C coils. METHODS: The proposed GRE sequence (slice selective RF pulse, slice thickness 100 mm, 16 averages, 64 × 64 matrix size, 400 × 400 mm FOV, 60 Hz/px BW, 50° FA, 80 ms TR, 14 ms TE, cartesian acquisition trajectory) was comprehensively evaluated on four clinical 3 T systems, across three sites and two vendors. Thirteen coils were evaluated, including multiple surface coils (transmit/receive and receive only) and volume coils for different body parts. The GRE sequence was compared with a previously described chemical shift imaging (CSI) technique for QC of 13C coils. The GRE sequence is widely available and built into all MR systems. In contrast, the CSI sequence is more specialized and is not available for all imaging systems. RESULTS: A Passing-Bablok regression and a Spearman correlation of 0.78 demonstrated good agreement of the two methods. The GRE approach offers reduced acquisition time and simplified analysis with SNR trends demonstrating reproducible coil performance across all sites and vendors. CONCLUSION: This standardization aims to strengthen multi-center trials by ensuring data comparability and reliability, advancing the clinical translation of 13C MRS methodologies. The results and analysis pipeline is made publicly available to facilitate implementation and coil comparisons across institutions.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

Multi-Vendor and Multi-Site Characterization of 13C Coils for Clinical Studies. — 科研速览 Science Skim