Tradeoff tuning via continuous organ‐at‐risk priority input for AI‐Generated intensity‐modulated radiation therapy plans for head‐and‐neck cancer

Xinyi Li, Yang Sheng, Dongrong Yang, Xin Wu, Yaorong Ge, Qiuwen Wu, Q. Jackie Wu

Key points

From the paper's conclusion
  • Conclusions The AI system can generate substantially different AI plans for the same patient according to the OAR sparing priority input.

Abstract

Background In current clinical practice, tradeoffs in treatment planning are handled by using multi‐criteria optimization (MCO) algorithms or manual operations; very few AI models are capable of handling tradeoffs. Purpose To design an Artificial Intelligence (AI) system that generates fluence maps with tunable tradeoffs, and to examine its performance in head‐and‐neck (HN) intensity modulated radiation therapy (IMRT) treatment. Methods User‐tunable, continuous organ‐at‐risk (OAR) priorities were conditioned into an AI‐driven auto‐planning system that predicts fluence maps for IMRT plans. Two separate AI models were developed and assembled sequentially for the auto‐planning process. The first model predicted individual IMRT field dose using anatomy, tradeoff preferences, and beam configurations as inputs, followed by the second model that generated fluence maps. The two models were trained independently before being integrated for automatic plan generation. A total of 230 patients were included in this study (200/5/25 for training/validation/testing). Two IMRT plans were generated for each training case. One used a set of original priorities adopted from clinical planning template that had balanced dose tradeoffs among OARs and planning target volume (PTV); the other used the same set of dose‐volume objectives while OAR sparing priorities were randomly altered by up to ± 20%. To examine the AI system's performance, three tests were designed to examine AI plans with a wide range of OAR priorities under different clinical scenarios. Results All AI plans using original OAR priorities have clinically acceptable dose distributions. As the OAR priorities change, dose distributions and dose volume histograms (DVHs) in the AI plans change accordingly within the −40% to +80% adjustment range. The dose metrics in AI plans have monotonic response to the corresponding input priorities, with high priorities achieving more sparing. Subtle secondary dose tradeoffs among OARs are also observed. Conclusions The AI system can generate substantially different AI plans for the same patient according to the OAR sparing priority input. The AI‐predicted fluence maps are computationally efficient, making intuitive tradeoff tuning real‐time. Further, this study demonstrates the promising performance of the AI system beyond traditional inverse planning loop and may potentially enhance AI's adoption in clinical planning process.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Tradeoff tuning via continuous organ‐at‐risk priority input for AI‐Generated intensity‐modulated radiation therapy plans for head‐and‐neck cancer — Science Skim