Tradeoff tuning via continuous organ‐at‐risk priority input for AI‐Generated intensity‐modulated radiation therapy plans for head‐and‐neck cancer
Xinyi Li, Yang Sheng, Dongrong Yang, Xin Wu, Yaorong Ge, Qiuwen Wu, Q. Jackie Wu
Key points
From the paper's conclusion- Conclusions The AI system can generate substantially different AI plans for the same patient according to the OAR sparing priority input.
Abstract
Background In current clinical practice, tradeoffs in treatment planning are handled by using multi‐criteria optimization (MCO) algorithms or manual operations; very few AI models are capable of handling tradeoffs. Purpose To design an Artificial Intelligence (AI) system that generates fluence maps with tunable tradeoffs, and to examine its performance in head‐and‐neck (HN) intensity modulated radiation therapy (IMRT) treatment. Methods User‐tunable, continuous organ‐at‐risk (OAR) priorities were conditioned into an AI‐driven auto‐planning system that predicts fluence maps for IMRT plans. Two separate AI models were developed and assembled sequentially for the auto‐planning process. The first model predicted individual IMRT field dose using anatomy, tradeoff preferences, and beam configurations as inputs, followed by the second model that generated fluence maps. The two models were trained independently before being integrated for automatic plan generation. A total of 230 patients were included in this study (200/5/25 for training/validation/testing). Two IMRT plans were generated for each training case. One used a set of original priorities adopted from clinical planning template that had balanced dose tradeoffs among OARs and planning target volume (PTV); the other used the same set of dose‐volume objectives while OAR sparing priorities were randomly altered by up to ± 20%. To examine the AI system's performance, three tests were designed to examine AI plans with a wide range of OAR priorities under different clinical scenarios. Results All AI plans using original OAR priorities have clinically acceptable dose distributions. As the OAR priorities change, dose distributions and dose volume histograms (DVHs) in the AI plans change accordingly within the −40% to +80% adjustment range. The dose metrics in AI plans have monotonic response to the corresponding input priorities, with high priorities achieving more sparing. Subtle secondary dose tradeoffs among OARs are also observed. Conclusions The AI system can generate substantially different AI plans for the same patient according to the OAR sparing priority input. The AI‐predicted fluence maps are computationally efficient, making intuitive tradeoff tuning real‐time. Further, this study demonstrates the promising performance of the AI system beyond traditional inverse planning loop and may potentially enhance AI's adoption in clinical planning process.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Reference‐Free large language model agents for physician‐guided radiotherapy treatment planningMedical Physics · 2026
- Agentic AI for Precision Radiotherapy: A Multi-Agent Framework for Clinical Decision SupportRadiation · 2026
- RadOnc-Agent: An LLM-Orchestrated Framework for AI Workflows Across the Radiotherapy Care PathwayarXiv · 2026
- A Large Language Model Framework for Seed Implant Brachytherapy: Adaptive Weight Optimization via Retrieval-Augmented Generation.Annals of the New York Academy of Sciences · 2026
- Trustworthy artificial intelligence in radiation oncology: cross-industry lessons for development, validation, and deployment.Frontiers in oncology · 2026
- RadOncGym: An Agent-Based Framework for Radiotherapy Dose-Mimicking OptimizationarXiv · 2026