From the paper's conclusion
  • In this work, industrial C12200 copper tubes with 0, 7 and 12 ppm trace lanthanum (La) additions were fabricated, and the effects of La on microstructure and chloride pitting resistance were systematically investigated via EBSD, salt spray test, electrochemical measurement and chloride transport simulation.

Abstract

Chloride‐induced pitting corrosion is a critical factor limiting the service life of C12200 precision copper tubes for air‐conditioning heat exchangers. In this work, industrial C12200 copper tubes with 0, 7 and 12 ppm trace lanthanum (La) additions were fabricated, and the effects of La on microstructure and chloride pitting resistance were systematically investigated via EBSD, salt spray test, electrochemical measurement and chloride transport simulation. La regulates the microstructural uniformity of copper tubes through a two‐stage mechanism. The 12 ppm La sample achieves remarkably enhanced pitting resistance via the synergistic effect of matrix purification, microstructure homogenization and corrosion product film densification. This work provides a theoretical basis for the composition design of long‐life precision copper tubes.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Effect of Trace Lanthanum Microalloying on Pitting Corrosion Resistance of C12200 Precision Copper Tubes in Chloride Environment — Science Skim