Evaluation of Fundus Radiation Intensity During Femtosecond Photoemulsification Cataract Surgery.
Haijun Lv, Jiaxin Lei, Chao Zhang, Hao Zhang, Zuowei Wang, Enpei Yang, Chenxi Liu, Shangbin Chen,
Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan, China.
Key points
From the paper's conclusion- Conclusions The measured fundus radiation power during femtosecond photoemulsification remained below the retinal safety threshold, supporting the retinal safety of this surgical mode under the tested conditions.
Abstract
OBJECTIVES: Femtosecond photoemulsification cataract surgery requires a higher total laser dose than conventional femtosecond laser-assisted cataract surgery, raising concerns about potential retinal exposure. This study aimed to develop a method for accurately measuring time-averaged fundus optical power and aperture-averaged irradiance during femtosecond photoemulsification and to evaluate retinal safety under the tested conditions. MATERIALS AND METHODS: A biomimetic cataract eye model was constructed using an artificial cornea, a hydrogen peroxide-induced cataractous rabbit lens, and saline to simulate the ocular media. A femtosecond laser system was used to perform lens fragmentation at pulse energies of 5.0, 6.0, 7.0, and 8.0 μJ. Time-averaged optical power reaching the simulated macular region was measured with a power meter and converted to aperture-averaged irradiance over a 5-mm receiving aperture. Post-ablation bubble morphology was observed using optical microscopy. RESULTS: At the effective pulse energy of 7.0 μJ, the maximum measured time-averaged aperture-averaged irradiance in the simulated macular region was 0.249 ± 0.025 W/cm2. Even at the excessive pulse energy of 8.0 μJ, the time-averaged aperture-averaged irradiance remained below the 0.7 W/cm2 retinal thermal limit recommended by the ICNIRP/Sliney guideline. CONCLUSIONS: The measured fundus radiation power during femtosecond photoemulsification remained below the retinal safety threshold, supporting the retinal safety of this surgical mode under the tested conditions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Femtosecond laser-assisted cataract surgery versus phacoemulsification in shallow anterior chambers: a systematic review and meta-analysis.Journal of cataract and refractive surgery · 2026
- Effect of temperature variation on the corneal endothelial cell during femtosecond laser-assisted cataract surgery compared with conventional phacoemulsification cataract surgery: A prospective studyMedicine · 2026
- Improved pulse-to-pulse energy stability measurements for sub-percent noise femtosecond lasersEPJ Web of Conferences · 2026
- Comparing Outcomes of Femtosecond Laser-Assisted Cataract Surgery and Conventional Phacoemulsification in a Randomized Controlled Trial.Journal of visualized experiments : JoVE · 2026
- Millimeter-Scale Wide-Field Mid-Infrared Photothermal Imaging Enabled by a Broadly Tunable Picosecond Optical Parametric OscillatorChemical & Biomedical Imaging · 2026
- Reference-state transferability limits in IR140: working-solution spectroscopy, bleachable optical depth, and apparent femtosecond saturation.Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2026