Efficacy of Intratympanic Sodium Thiosulfate Gel Injection to Prevent Cisplatin-Induced Ototoxicity.
Kunyakorn Vittayakoonsakulchai, Pittayapon Pitathawatchai, Yuvatiya Plodpai, Viraporn Atchariyasathian, Wandee Khaimook, Virat Kirtsreesakul, Rungarun Kittichet, Pattarawadee Prayuenyong
Department of Otolaryngology - Head and Neck Surgery, Faculty of Medicine, Prince of Songkla University, Hat Yai, Thailand. · Department of Radiology, Faculty of Medicine, Prince of Songkla University, Hat Yai, Thailand.
Key points
From the paper's conclusion- Objective This study aimed to evaluate the efficacy and safety of intratympanic sodium thiosulfate (STS) gel injection in preventing cisplatin‐induced hearing loss.
Abstract
OBJECTIVE: This study aimed to evaluate the efficacy and safety of intratympanic sodium thiosulfate (STS) gel injection in preventing cisplatin-induced hearing loss. METHODS: We conducted a single-blinded randomized controlled trial, enrolling adults with head and neck cancer undergoing cisplatin chemotherapy. Intratympanic STS gel was injected into one ear within 3 h before each cisplatin cycle, while the contralateral ear served as a control. Clinical and audiometric assessments were performed before each injection and 1-3 months after the completion of chemotherapy. Changes in hearing thresholds from baseline at each frequency were measured. Ototoxicity was defined according to the American Speech-Language-Hearing Association (ASHA) criteria. Adverse events associated with intratympanic STS gel injections were also monitored. RESULTS: Twenty-eight patients were included in the study. Based on ASHA criteria within the frequency range of 0.25-8 kHz, there was no statistically significant difference in the incidence of ototoxicity between the treated and control ears (p = 0.683). Compared with control ears, treated ears exhibited significantly reduced threshold shifts from baseline in the 4, 6, 8, 9, and 11 kHz, with mean differences of approximately 7-10 dB. A safety analysis of 74 injections revealed minor adverse effects, including otalgia (10.8%), transient vertigo (10.8%), dizziness (14.8%), and tympanic membrane perforation (4.0%). CONCLUSION: Our findings showed no significant difference in the incidence of cisplatin ototoxicity between STS injected and control ears. Nonetheless, intratympanic STS gel injections demonstrated potential benefits in preserving hearing at high and extended-high frequencies. The procedure was generally well-tolerated, with manageable adverse effects. LEVEL OF EVIDENCE: N/A.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Intratympanic Steroid Regimen for Prevention of Cisplatin-Induced Hearing Loss: A Systematic Review.Audiology & neuro-otology · 2026
- Otoprotection in Children Treated for Cancer: A CODEPEH Structured Narrative Review on Pharmacological Agents, Biomarkers and Genetic SusceptibilityRomanian Journal of Preventive Medicine · 2026
- Standardizing ototoxicity monitoring for children treated with cisplatin: an urgent call to action.Frontiers in oncology · 2026
- Pharmacokinetics, Safety, and Efficacy of High-Concentration Intratympanic Dexamethasone for Sudden Sensorineural Hearing Loss: An Integrated Non-Human Primate and Clinical Study.European journal of pharmaceutical sciences : official journal of the European Federation for Pharmaceutical Sciences · 2026
- Systemic oral steroids versus intratympanic steroid injection in idiopathic sudden sensorineural hearing loss: a randomized controlled trialThe Egyptian Journal of Otolaryngology · 2026
- Cisplatin-Induced Ototoxicity in Head and Neck Cancer: A Systematic Review of Current Evidence, Clinical Implications, and the Need for Standardized Monitoring.Current oncology (Toronto, Ont.) · 2026