The Effect of Interposition Nerve Graft Length on Outcomes of Laryngeal Reinnervation.
Pranati Pillutla, Tereza Vitkovska, Maxwell L Weng, Ivan Lopez, Jennifer Long, Dinesh K Chhetri
Department of Head and Neck Surgery, University of California, Los Angeles, California, USA. · David Geffen School of Medicine, University of California, Los Angeles, California, USA.
Key points
From the paper's conclusion- Longer interposition grafts were associated with reduced axonal counts and increasingly abnormal NMJ morphology. These findings suggest longer interposition graft lengths may reduce laryngeal reinnervation outcomes.
Abstract
OBJECTIVE: To evaluate the impact of interposition graft lengths on the efficacy of laryngeal reinnervation. METHODS: In an in vivo rabbit model, unilateral recurrent laryngeal nerve (RLN) resection was performed followed by immediate re-anastomosis using interposition graft lengths of 0, 2, 4, and 6 cm (N = 2 animals per length). After 4 months, thyroarytenoid (TA) muscles and RLNs were harvested and analyzed. Muscle fiber area was assessed using hematoxylin-eosin staining. Neuromuscular junctions (NMJs) were identified by immunohistochemistry for post-synaptic acetylcholine receptors and categorized morphologically as pretzel shape (normally innervated), fragmented (partially innervated), or plaque-like (degenerated). Axons within RLN segments were visualized using FluoroMyelin lipid-fluorescent staining. RESULTS: Muscle fiber area tended to be decreased on the experimental side but did not differ significantly across graft lengths. Normal contralateral muscles showed 100% pretzel morphology. NMJ morphology progressively worsened with increasing graft length: 0 cm grafts (62% pretzel; 38% fragmented; 0% plaque), 2 cm (23%; 69%; 8%), 4 cm (15%; 54%; 31%), and 6 cm (18%; 36%; 46%). Axon count in the distal RLN segment as a percentage of axons in the proximal RLN segment similarly declined with graft length: 0 cm grafts (mean 136%), 2 cm (51%), 4 cm (19%), and 6 cm (17%). CONCLUSION: Longer interposition grafts were associated with reduced axonal counts and increasingly abnormal NMJ morphology. These findings suggest longer interposition graft lengths may reduce laryngeal reinnervation outcomes. LEVEL OF EVIDENCE: n/a.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Donor-Derived Fibrin Matrix as an Adjunct to Microsurgical Recurrent Laryngeal Nerve Repair: An Experimental Rat Study.Biomedicines · 2026
- Topographic and histomorphometric analysis of the stylohyoid nerve: A novel donor candidate for facial reanimation.Journal of plastic, reconstructive & aesthetic surgery : JPRAS · 2026
- Reducing Cross‐Face Nerve Graft Length by Mobilizing the Recipient Facial Nerve Stump: A Cadaveric StudyMicrosurgery · 2026
- Establishment of recurrent laryngeal nerve injury animal models using intraoperative neural monitoring: SD rat models.Frontiers in endocrinology · 2026
- Laryngeal branches of the recurrent laryngeal nerve: A narrative review of human anatomical studies.Anatomical record (Hoboken, N.J. : 2007) · 2026
- Novel Injectable Supports Long-Term Recurrent Laryngeal Nerve and Partial Peripheral Nerve Repair.The Laryngoscope · 2026