The biplanar cut in medial closing-wedge distal femoral osteotomy is associated with a four-fold lower rate of lateral hinge fractures at non-inferior coronal correction.
Alessio Maione, Pierrenzo Pozzi, Simone Gallizzi, Matteo Davide Parmigiani, Simone Romano, Alessandra Menon, Filippo Calanna, Riccardo Compagnoni,
U.O.C. I Clinica Ortopedica, ASST Gaetano Pini-CTO, Milan, Italy. · U.O.C Week Surgery, ASST Gaetano Pini-CTO, Milan, Italy.
Key points
From the paper's conclusion- These findings warrant prospective investigation of the biplanar technique as a potentially preferable approach for MCW‐DFO.
Abstract
PURPOSE: This study compares the outcomes of medial closing-wedge distal femoral osteotomy (MCW-DFO) performed with a monoplanar versus a biplanar technique, evaluating radiological correction as primary outcome and hinge fracture incidence, overall complication profile and patient-reported outcome measures as secondary outcomes. METHODS: A retrospective analysis was conducted on a consecutive series of 82 patients (86 knees) with genu valgum who underwent MCW-DFO between 2010 and 2024. Patients were divided into a monoplanar group (44 knees) and a biplanar group (42 knees). Primary outcome was the evaluation of the hip-knee-ankle angle (HKA) and lateral distal femoral angle (LDFA), assessed on weight-bearing full-length radiographs pre- and postoperatively. Secondary outcomes included hinge fracture incidence, overall complication rate and patient-reported outcome measures (PROMs) comprising the International Knee Documentation Committee score, Knee Society Score, Knee Injury and Osteoarthritis Outcome Score, Tegner Activity Scale and Visual Analogue Scale for pain. RESULTS: Both groups achieved equivalent and significant coronal correction, with no between-group differences in postoperative HKA (180.1° ± 2.5° vs. 179.8° ± 4.4°, p = 0.502) or LDFA (90.7° ± 2.6° vs. 91.5° ± 4.1°, p = 0.339). Hinge fractures were significantly more frequent in the monoplanar group (75.0% vs. 19.0%, p < 0.001), and non-inferiority of the biplanar technique was formally demonstrated for all radiographic parameters. All PROMs improved significantly from baseline in both groups, with the magnitude of improvement exceeding the minimal clinically important difference thresholds for all scores. CONCLUSIONS: Biplanar MCW-DFO protocol was associated with a lower incidence of lateral hinge fractures than monoplanar procedure, while achieving comparable coronal correction, as formally confirmed by non-inferiority testing. Although trends toward better activity level and pain relief were observed in the biplanar group, these differences did not retain statistical significance and should be considered hypothesis-generating. These findings warrant prospective investigation of the biplanar technique as a potentially preferable approach for MCW-DFO. LEVEL OF EVIDENCE: Level III, case-control study.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Osteotomies Around the Knee - a Narrative Review of the Current Standard.Zeitschrift fur Orthopadie und Unfallchirurgie · 2026
- Bidirectional joint line convergence angle changes and their preoperative predictors 12 months after medial closing-wedge distal femoral osteotomy for valgus knees: A single-centre exploratory study.Journal of experimental orthopaedics · 2026
- Lateral Opening-Wedge Versus Medial Closing-Wedge Distal Femoral Osteotomy for Adolescent Idiopathic Genu Valgum: A Randomised Controlled Trial.Journal of pediatric orthopedics · 2026
- Anteromedial osteotomy and distraction are associated with greater posterior tibial slope increase after medial open-wedge high tibial osteotomy: A retrospective comparison of three techniques.Journal of orthopaedic surgery (Hong Kong) · 2026
- Osteotomía desrotadora femoral diafisiaria para realineación patelofemoral: indicación, técnica y resultadosRELART | Revista Latinoamericana de Artroscopia Reconstrucción Articular y Trauma Deportivo · 2026
- No significant change in tibial torsion despite hinge fracture after high tibial osteotomy using patient-specific instruments.Journal of experimental orthopaedics · 2026