Journal of separation science

Validated High-Performance Thin-Layer Chromatography Method for Multi-Marker Analysis in Ayurvedic Polyherbal Formulations With Orthogonal Confirmation Using Mass Spectrometry.

Mukesh N Kher, Utsav G Gajera, Ravi Patel, Govind J Kher, Priyanka O Sihag

Department of Pharmaceutical Chemistry and Quality Assurance, L. M. College of Pharmacy, Ahmedabad, India. · School of Pharmacy, Gujarat Technological University, Gandhinagar, India.

Key points

From the paper's conclusion
  • The developed method offers a reliable, cost-effective, and high-throughput approach for routine quality control of AYUSH-64 and other complex polyherbal formulations containing CA, FA, CFA, and UA biomarkers, contributing to the global standardization and scientific validation of traditional Ayurvedic medicines.

Abstract

A novel, specific, sensitive, accurate, and reproducible high-performance thin-layer chromatography (HPTLC) method has been developed and validated for the simultaneous estimation of four key biomarkers: chlorogenic acid (CA), ferulic acid (FA), caffeic acid (CFA), and ursolic acid (UA) from commercially available Ayurvedic polyherbal formulation AYUSH-64. A pre-coated silica gel 60F254 aluminum plate was used as a stationary phase for the separation and quantification of the selected markers. A quaternary solvent system comprising toluene: chloroform: ethyl acetate: formic acid (3:1:4:2, v/v/v/v) was optimized to achieve effective separation. The analytes were detected at 254 and 366 nm (CA, FA, and CFA) and 590 nm (UA and post-derivatization), with well-resolved retardation factor values of 0.20, 0.70, 0.77, and 0.89, respectively. By matching the retardation factor values with authentic standards, the selected markers were identified and further confirmed using ultra-high-performance liquid chromatography coupled with electrospray ionization and a triple quadrupole tandem mass spectrometer. The developed method was validated as per the International Council for Harmonization guideline. The method exhibited excellent linearity (r2 > 0.995), precision (relative standard deviation <2%), and accuracy (98%-102%). The limit of detection values were found to be 3.6, 7.7, 5.4, and 34.3 ng/band, while the limit of quantification values were 10.9, 23.4, 16.5, and 103.8 ng/band for CA, FA, CFA, and UA, respectively. This is the first report of a validated HPTLC method enabling simultaneous estimation of four selected biomarkers using a single mobile phase system, despite their diverse polarity profiles and detection challenges. The developed method offers a reliable, cost-effective, and high-throughput approach for routine quality control of AYUSH-64 and other complex polyherbal formulations containing CA, FA, CFA, and UA biomarkers, contributing to the global standardization and scientific validation of traditional Ayurvedic medicines.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Validated High-Performance Thin-Layer Chromatography Method for Multi-Marker Analysis in Ayurvedic Polyherbal Formulations With Orthogonal Confirmation Using Mass Spectrometry — Science Skim