From the paper's conclusion- These results indicate that feature‐band‐based mid‐level FTIR‐Raman fusion provides an effective balance between complementary information integration and redundancy reduction, offering a feasible approach for rapid assessment of transformer insulation condition.
Abstract
This study proposes a multilevel data‐fusion approach combining Fourier transform infrared (FTIR) and Raman spectroscopy for the rapid quantification of furfural in transformer oil. Oil samples representing different aging stages were prepared through accelerated thermal aging of oil–paper insulation, and furfural reference concentrations were determined by high‐performance liquid chromatography (HPLC). Density functional theory (DFT) calculations were further used to interpret the vibrational characteristics of furfural and elucidate the key spectral responses and complementarity between FTIR and Raman spectroscopy. Based on these data, quantitative models were first developed for each spectroscopic modality and subsequently extended to low‐, mid‐, and high‐level fusion strategies. For single‐spectroscopy modeling, the best‐performing FTIR model achieved a prediction‐set coefficient of determination () of 0.9342 and a root mean square error of prediction (RMSEP) of 2.6030 mg/L, whereas the best‐performing Raman model yielded an of 0.9601 and an RMSEP of 2.0253 mg/L. Among the evaluated fusion strategies, mid‐level fusion achieved the best numerical prediction performance. The best‐performing k‐nearest neighbors (KNN) model achieved an of 0.9606 and an RMSEP of 2.0134 mg/L, showing only a marginal improvement compared with the best Raman‐only model ( = 0.9601, RMSEP = 2.0253 mg/L). Within the low‐concentration range of 0–4 mg/L, the root mean square error (RMSE) and mean absolute error (MAE) were 0.6253 and 0.3753 mg/L, respectively, with a bias of −0.0234 mg/L. These results indicate that feature‐band‐based mid‐level FTIR‐Raman fusion provides an effective balance between complementary information integration and redundancy reduction, offering a feasible approach for rapid assessment of transformer insulation condition.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Enhancing weak Raman spectral fingerprints for multi-source walnut oil adulteration using multi-level feature fusion.Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2026
- Interpretable multimodal fusion of near-infrared spectroscopy and color features for online monitoring of honey refining process.Food chemistry · 2026
- Developing a Sustainable FTIR Spectroscopic Method for Quantifying Unsaturation in Commercially Available Edible OilsJournal of the American Oil Chemists' Society · 2026
- SERS-Enabled Direct Detection of Furfural in a Complex Oil Mixture.Sensors (Basel, Switzerland) · 2026
- Multi-source fusion of NIR and UV spectroscopy with refractometry for pooled prediction of total flavonoids, total polyphenols and solids content in herbal water extracts.Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2026
- Chemically informed spectro-structural feature augmentation for interpretable NIR chemometric classification of fuel grades.Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2026