Association between augmented enteral protein and muscle mass attenuation in critically ill patients: A sub-study of a cluster randomized crossover trial.
Matthew J Summers, Elizabeth Viner Smith, Kate Hadley-Brown, Amalia Karahalios, Tara D'Arcy, Imogen E Asser, Mark P Plummer, Terri Follett,
School of Medicine, College of Health, Adelaide University, Adelaide, South Australia, Australia. · Intensive Care Unit, Wellington Regional Hospital, Wellington, New Zealand.
Key points
From the paper's conclusion- Conclusion No clear difference was detected in quadriceps muscle layer attenuation over 7 days between augmented enteral protein and usual protein.
Abstract
BACKGROUND: Critically ill patients experience muscle wasting, impacting recovery. The associations between augmented enteral protein and muscle mass, strength, physical function, and quality of life are uncertain. METHODS: We performed a sub-study in adult TARGET Protein participants from two sites between 23/11/2022-23/05/2023. Our exposure of interest was enteral formula with augmented protein (100 g protein/L) and comparator usual protein formula (63 g protein/L), which were isocaloric. Our primary outcome was the change in quadriceps muscle layer thickness from Days 1 to 7, determined by ultrasonography and compared between groups. Our secondary outcomes were group differences in handgrip strength, change in physical function, and quality of life. Data are numbers (%), mean (standard deviation), and differences with 95% confidence intervals (CI). RESULTS: Seventy-two patients were included (augmented protein n = 46, 61 (16)y, 65% male; usual protein n = 26, 56 (16)y, 46% male), 56 had primary outcome data (augmented protein n = 35; usual protein n = 21). Delivered protein was higher with augmented protein (1.2 (0.4) vs 0.8 (0.3) g/kg/day). Quadriceps muscle layer thickness decreased in both groups, with change from Days 1 to 7 similar (0.01 cm; 95% CI, -0.27, 0.28; P = 0.970). Left handgrip strength at ICU discharge and quality of life at Day 90 were similar. Augmented protein was associated with greater right handgrip strength at ICU discharge (6.23; 95% CI, 0.67, 11.79) and was associated with greater decline in physical function at ICU discharge (-15.00; 95% CI, -19.75, -10.25), but not at Day 90. CONCLUSION: No clear difference was detected in quadriceps muscle layer attenuation over 7 days between augmented enteral protein and usual protein. TRIAL REGISTRATION: Australian New Zealand Clinical Trials Registry identifier: ACTRN12622001465741.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- High versus standard-protein provision and muscle loss in critically ill patients assessed by muscle ultrasound: A prospective ancillary study of a randomised controlled trial.Clinical nutrition (Edinburgh, Scotland) · 2026
- Combined intravenous bolus amino acid supplementation and mobilization on early muscle loss in critically ill adults: A randomized controlled trialJournal of Parenteral and Enteral Nutrition · 2025
- Effects of higher versus lower protein intake in critically ill patients: a systematic review and meta-analysis.Frontiers in nutrition · 2026
- Increasing protein dose does not further augment muscle protein synthesis in critical illness: a randomized, controlled clinical trialAmerican Journal of Respiratory and Critical Care Medicine · 2026
- The effect of augmented protein intake on nitrogen balance: A nested cohort study of the TARGET protein trial.Journal of critical care · 2026
- The efficacy of high-protein nutritional support on mortality, clinical outcomes, and nutritional adequacy in critically ill patients: a double‑center randomized controlled trialNutrition & Metabolism · 2025