Totally Thoracoscopic Atrial Fibrillation Ablation With the Gemini S Bipolar Clamp: A Single-Center Descriptive Cohort Study of 1-Year Rhythm, Safety, and Quality-of-Life Outcomes.
Michal Gruszczynski, Hector Rodriguez Cetina Biefer, Laura Rings, Sacha P Salzberg, Vasileios Ntinopoulos, Omer Dzemali
Department of Cardiac Surgery City Hospital of Zurich-Triemli Zurich Switzerland. · Herzklinik Swiss Ablation Zurich Switzerland.
Key points
From the paper's conclusion- We describe 1‐year outcomes in a consecutive cohort.
Abstract
BACKGROUND: Outcome data for the Gemini S bipolar radiofrequency clamp are almost absent; the only indexed report being a three-patient case series. We describe 1-year outcomes in a consecutive cohort. METHODS: We retrospectively analyzed all consecutive patients treated with the Gemini S clamp between January 2021 and August 2024. Epicardial box isolation was combined with left atrial appendage (LAA) exclusion; completeness was confirmed by entry and exit block on epicardial three-dimensional mapping. The primary outcome was freedom from AF recurrence at 12 months, on and off antiarrhythmic drugs (AADs) after a 90-day blanking period. RESULTS: Twenty-three patients were included (mean age 64.4 ± 8.0 years; 82.6% male). AF was paroxysmal in 34.8%, persistent in 26.1%, and long-standing persistent in 39.1%; 60.9% had prior catheter ablation and 69.6% had failed or were intolerant to a Class I or III agent. A complete block-verified box lesion was achieved in 95.7% and LAA exclusion in 91.3%. Three patients (13.0%) required conversion to sternotomy for bleeding, exceeding larger series. There was no death, stroke, phrenic nerve palsy, or pacemaker implantation. At 1 year, 87.0% (95% CI 67.9-95.5) were in sinus rhythm, all off Class I/III AADs. CONCLUSIONS: Sinus rhythm was achieved in 87.0% of patients at 1 year. As the largest reported experience with this device, the series provides device-level evidence where little existed, but it is descriptive, not powered for comparison, and the conversion rate needs confirmation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The feasibility of same-day discharge for the epicardial component of convergent hybrid ablationEuropean Heart Journal · 2026
- Differential Recurrence Risk in Paroxysmal Versus Persistent Atrial Fibrillation Post-Catheter Ablation: HFpEF as an Independent Predictor.Journal of cardiovascular development and disease · 2026
- Safety of hybrid epicardial–endocardial ablation in patients with persistent atrial fibrillation and heart failure with reduced left ventricular ejection fractionEuropean Heart Journal · 2026
- Adjunctive empirical superior vena cava isolation with fourth-generation cryoballoon in paroxysmal atrial fibrillation does not improve outcomes and increases complications: the randomized CISPAF trial.Frontiers in cardiovascular medicine · 2026
- Surgical Treatment of Atrial Fibrillation.Circulation · 2026
- Outcomes of surgical ablation for atrial fibrillation in adults with congenital heart disease.General thoracic and cardiovascular surgery · 2026