Journal of Medical Radiation Sciences

Diagnostic Performance, Image Quality and Radiation Dose of Ultra‐Low Dose Chest CT Compared With Chest Radiography for Latent Tuberculosis Screening: Influence of Image Reconstruction Techniques

Niamh Moore, Ronan Lee, Eid Kakish, Sahil Shet, Ludolf DeKock, Patrick O'Regan, Davida Hehir, Michael Waldron,

Observational · n=12

Key points

From the paper's conclusion
  • This study evaluated the diagnostic performance, image quality, and radiation dose of ultra‐low‐dose CT (ULDCT) compared with chest radiography (CXR) for detecting radiological features of LTBI.

Abstract

Introduction Latent tuberculosis infection (LTBI) affects over one quarter of the global population and poses a significant risk of reactivation in immunocompromised patients. Accurate radiological assessment is essential before initiating immunosuppressive therapies. This study evaluated the diagnostic performance, image quality, and radiation dose of ultra‐low‐dose CT (ULDCT) compared with chest radiography (CXR) for detecting radiological features of LTBI. Methods In this prospective single‐centre study, adults undergoing LTBI screening prior to immunosuppressive therapy underwent standard CXR and ULDCT. Subjective image quality was independently assessed by two radiologists who were blinded to the outcomes, while objective image quality assessment was performed by a single radiologist. LTBI‐related findings were recorded. Statistical analyses included interobserver agreement, paired modality comparison, and radiation dose assessment. Results Thirty‐four participants (BMI 28.6 ± 6.9 kg/m 2 ) were included. The mean ± SD effective dose for ULDCT was 0.13 ± 0.02 mSv in comparison to 0.10 ± 0.07 mSv for the CXR. ULDCT detected granulomas in 12 patients (16 lesions); CXR detected none of the CT‐confirmed granulomas; maximum intensity projections identified additional lesions. CXR sensitivity for granuloma detection was 0% (95% CI: 0%–26.5%) when CT was used as the reference. ULDCT also identified pulmonary nodules, mediastinal lymphadenopathy, calcified nodes, and incidental findings not visible on CXR, including features suspicious for active tuberculosis in two cases. Conclusion The results indicate that ULDCT is superior to CXR for detecting calcified granulomas and other LTBI‐related thoracic findings at comparable radiation doses.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Diagnostic Performance, Image Quality and Radiation Dose of Ultra‐Low Dose Chest CT Compared With Chest Radiography for Latent Tuberculosis Screening: Influence of Image Reconstruction Techniques — Science Skim