Journal of experimental orthopaedics

Arthroscopic tie-knot versus suture bridge fixation for anterior cruciate ligament tibial avulsion fractures: A 5-year comparative study.

Zhe Liu, Jing Guo, Haoxin Li, Haifeng Yuan

General Hospital of Ningxia Medical University Ningxia China. · Hainan District People's Hospital Inner China.

Observational · n=146

Key points

From the paper's conclusion
  • Purpose To compare perioperative outcomes, radiographic healing, recovery trajectories and 5‐year clinical outcomes after arthroscopic tie‐knot (TK) and suture bridge (SB) fixation of anterior cruciate ligament (ACL) tibial avulsion fractures.

Abstract

PURPOSE: To compare perioperative outcomes, radiographic healing, recovery trajectories and 5-year clinical outcomes after arthroscopic tie-knot (TK) and suture bridge (SB) fixation of anterior cruciate ligament (ACL) tibial avulsion fractures. METHODS: This single-center retrospective comparative cohort study identified 146 adults treated between 19 December 2017, and 31 August 2020. After clinical exclusions and incomplete 5-year follow-up, 90 patients formed the complete-case cohort (TK, n = 42; SB, n = 48). Longitudinal visual analog scale (VAS), International Knee Documentation Committee (IKDC), Lysholm, range-of-motion (ROM) and KT-1000 side-to-side laxity outcomes were analyzed using covariate-adjusted generalized estimating equations (GEEs). Holm correction was applied across the five global group-by-time tests and within each outcome for postoperative contrasts. RESULTS: Operative time was 12.47 min longer with SB fixation (95% confidence interval [CI], 8.58-16.36; p < 0.001), whereas the recorded radiographic-healing interval was 0.76 weeks shorter (95% CI, 0.14-1.38 weeks shorter; p = 0.017). After Holm correction across outcome domains, group-by-time interactions remained significant for International Knee Documentation Committee (IKDC) (adjusted p = 0.013) and Lysholm (adjusted p = 0.048), but not VAS (p = 0.069), ROM (p = 0.069), or KT-1000 (p = 0.266). Exploratory within-outcome contrasts showed small 1-month differences in VAS, IKDC, Lysholm, and ROM; no between-group difference persisted from 6 months to 5 years. CONCLUSION: Both fixation strategies were associated with favorable 5-year knee function and stability. SB fixation required longer operative time and was associated with a slightly shorter recorded healing interval and small early differences of uncertain clinical importance. The nonrandomized design and residual confounding preclude claims of technique superiority. LEVEL OF EVIDENCE: Level III, retrospective comparative cohort study.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Arthroscopic tie-knot versus suture bridge fixation for anterior cruciate ligament tibial avulsion fractures: A 5-year comparative study — Science Skim