Can frontier vision-language models support first-pass orthopaedic landmark annotation? A zero-shot technical feasibility study of 553 lateral knee radiographs.
Prushoth Vivekanantha, Satyavenkata Kotipalli, Marc Daniel Bouchard, Ashraf Hantouly, Jeffrey Kay, Darren de Sa, Olufemi R Ayeni
Division of Orthopedic Surgery, Department of Surgery McMaster University Hamilton Ontario Canada.
Key points
From the paper's conclusion- This study evaluated the ability of GPT‐5.5 to perform zero‐shot landmark localization on lateral knee radiographs.
Abstract
PURPOSE: Automated measurement of sagittal-plane knee parameters such as posterior tibial slope (PTS) and patellar height requires accurate anatomical landmark localization. Frontier vision-language models (VLMs) offer the potential to localize anatomical landmarks directly from textual definitions without task-specific training. This study evaluated the ability of GPT-5.5 to perform zero-shot landmark localization on lateral knee radiographs. METHODS: A total of 553 lateral knee radiographs were manually annotated to create a human reference containing four anatomical structures: patella, tibial plateau, tibial shaft and tibial tubercle. GPT-5.5 was prompted using the OpenAI Application Programming Interface to generate annotations directly in YOLOv8 pose format. Model outputs underwent schema adherence validation prior to comparison with human annotations. Localization performance was quantified using Euclidean distance in both normalized coordinate space and pixel space. Computational performance metrics included token usage, runtime and cost. RESULTS: GPT-5.5 successfully generated valid annotations for 552 of 553 radiographs, corresponding to schema validation success of 99.8%. Across 4416 landmark predictions, the mean (standard deviation [SD]) pixel localization error was 62.9 (69.3) pixels with a median (interquartile range) of 41.2 (23.1-77.3) pixels. Mean (SD) normalized localization error was 0.0376 (0.0325). The most accurately localized landmarks were the superior patellar pole (mean normalized error = 0.0240), inferior articular surface (0.0254) and inferior patellar pole (0.0259). Greater errors were observed for the distal tibial shaft (0.0561) and tibial tubercle (0.0515). Processing of all images cost $64.64 and required 11.9 h runtime. CONCLUSIONS: GPT-5.5 demonstrated the ability to localize anatomical landmarks on lateral knee radiographs using a zero-shot, definition-only prompting strategy with modest localization error. Although performance is insufficient for full independent deployment, VLMs show promise as first-pass annotation tools that may reduce the manual labelling burden associated with orthopaedic pose-estimation data sets. LEVEL OF EVIDENCE: Level IV.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Multimodal Large Language Models and Dental Students in Radiographic Landmark Identification: A Novel Grid-Based Assessment.Dento maxillo facial radiology · 2026
- VL-OrdinalFormer: Vision–Language-Guided Ordinal Transformers for Interpretable Knee Osteoarthritis GradingMathematics · 2026
- Comparative accuracy of large language models and orthopaedic clinicians in knee osteoarthritis and tibial plateau fracture classification systems.The Knee · 2026
- AFIDs-Validator: An Open-Access AI-Guided Platform for Learning Anatomical Landmark PlacementbioRxiv · 2026
- Accuracy of general-purpose large language models (LLMS) in interpreting adolescent idiopathic scoliosis radiographs: a comparative study with experienced spine surgeons.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
- Do Large Language Models Use the Clinical Vignette? A Question Ablation Study on the Orthopaedic In-Training ExaminationmedRxiv · 2026