Journal of experimental orthopaedics

MAKO robotic-assisted versus computed tomography-based navigated and conventional total hip arthroplasty in patients with developmental dysplasia of the hip: A systematic review and meta-analysis.

Amirhossein Amiri, Ariyan Ayati Firoozabadi, Sadra Mohebbi

Student Research Committee, School of Medicine Shahid Beheshti University of Medical Sciences Tehran Iran. · School of Medicine Tehran University of Medical Sciences Tehran Iran.

Meta-analysis

Key points

From the paper's conclusion
  • Purpose To compare implant positioning and clinical outcomes of MAKO robotic arm‐assisted total hip arthroplasty (R‐THA) with conventional THA (C‐THA) and computed tomography (CT)‐based navigated THA (N‐THA) in developmental dysplasia of the hip (DDH).

Abstract

PURPOSE: To compare implant positioning and clinical outcomes of MAKO robotic arm-assisted total hip arthroplasty (R-THA) with conventional THA (C-THA) and computed tomography (CT)-based navigated THA (N-THA) in developmental dysplasia of the hip (DDH). METHODS: This systematic review and meta-analysis followed Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) 2020 and the Cochrane Handbook. PubMed, Scopus, Web of Science and Embase were searched up to 30 October 2025. Eligible studies compared MAKO R-THA with C-THA and/or N-THA in DDH patients. Risk of bias was assessed using the Risk of Bias in Non-Randomized Studies of Interventions (ROBINS-I) tool. Meta-analysis was performed with STATA 18.0 using random-effects models. Pooled mean differences (MDs) and risk ratios (RRs) were calculated. Heterogeneity was assessed using the I 2 statistic, and the certainty of evidence was evaluated using the Grading of Recommendations, Assessment, Development and Evaluations (GRADE) framework. RESULTS: Nine observational studies involving 1130 hips (562 MAKO R-THA, 442 C-THA and 126 N-THA) were included. Compared with C-THA, MAKO R-THA significantly improved horizontal center of rotation (COR) restoration (MD = -1.01 mm, 95% confidence interval [CI] [-1.49 to -0.54]), while no significant differences were observed in operative time, intraoperative blood loss, vertical COR and overall complication rate. Compared with N-THA, MAKO R-THA achieved significantly smaller deviations from planned acetabular inclination (MD = -1.47°, 95% CI [-2.11 to -0.83]) and anteversion (MD = -1.60°, 95% CI [-2.21 to -0.99]). CONCLUSIONS: In patients with DDH, MAKO R-THA demonstrated small, statistically significant improvements in specific radiographic parameters (lower horizontal COR deviation vs. C-THA and smaller inclination and anteversion deviations vs. CT-based N-THA). However, these modest radiographic differences have not been shown to translate into superior clinical function, patient-reported outcomes or lower complication rates. Long-term studies are needed to determine whether these technical precision gains affect implant survivorship. LEVEL OF EVIDENCE: Level III.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers