Technical efficiency in hip arthroscopy plateaus after approximately 240 cases while complication rates continue to decline: A 15-year single-surgeon series of 1490 consecutive procedures.
Andrea Mei, Leonardo Clausetti, Martial Metrop, Guillaume Girardot, Nicolas Bonin
Università degli Studi di Milano, Scuola di Specializzazione in Ortopedia e Traumatologia Milano Italy. · Department of Orthopedic Surgery and Sport Medicine, Hospices Civils de Lyon, Hôpital de la Croix-Rousse Lyon France.
Key points
From the paper's conclusion- Conclusions In one of the largest single‐surgeon series reported, technical efficiency (traction time) stabilised at approximately 242 cases, whereas safety continued to improve well beyond this point.
Abstract
PURPOSE: To define the learning curve of a single surgeon performing hip arthroscopy using traction time as the primary metric of technical efficiency, and complication rate as a secondary endpoint, in a cohort large and long enough to model the inflection point with objective change-point methods. METHODS: A total of 1490 consecutive hip arthroscopies performed by one surgeon between January 2007 and April 2022 were retrospectively analysed. Cases were ordered chronologically and assigned a cumulative case number. Traction time was modelled against case number with Pearson correlation and a continuous two-phase (broken-stick) segmented regression; the breakpoint was estimated by grid-search minimisation of the residual sum of squares, with a 95% confidence interval from non-parametric bootstrap (400 resamples). A cumulative sum (CUSUM) chart was constructed. Experience phases were compared with the Welch t test, Mann-Whitney U test, and the two-proportion test. RESULTS: Traction time decreased with experience (r = -0.34; p < 0.001). Segmented regression identified a breakpoint at case 242 (95% confidence interval [CI], 208-258; model R 2 = 0.35): a first-phase decline of 1.6 min per 10 cases was followed by a plateau near 35 min; the CUSUM peak (case 224) corroborated this transition. Mean traction time fell from 54.8 to 35.6 min before versus after the breakpoint (p < 0.001). Graded with the validated modified Clavien-Dindo classification for hip preservation surgery, the patient-level complication rate decreased across consecutive phases from 14.7% (cases 1-150) to 3.1% (151-500) to 1.5% (501-1490), and continued to decline beyond the efficiency plateau; most complications were Grade I. CONCLUSIONS: In one of the largest single-surgeon series reported, technical efficiency (traction time) stabilised at approximately 242 cases, whereas safety continued to improve well beyond this point. In this single-surgeon experience, the learning curve extended over several hundred cases, well beyond the 20-30 cases reported in early small series; whether these thresholds apply to other surgeons and training contexts requires confirmation. LEVEL OF EVIDENCE: Level IV, therapeutic case series.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- EP9.18 Assessing the Learning Curve in Hip Arthroscopy: A Prospective Case Series Analysis of Operative Efficiency Over TimeJournal of Hip Preservation Surgery · 2026
- EP3.45 Factors Influencing Surgical Duration in Hip Arthroscopy: The Role of Surgeon Experience and Hip MorphologyJournal of Hip Preservation Surgery · 2026
- EP1.69 Learning curve in periacetabular osteotomy: a single-center retrospective studyJournal of Hip Preservation Surgery · 2026
- EP3.32 Traction-Assisted Capsular Technique (TACT): A Promising Method for Efficient and Reliable Capsular Closure in Hip ArthroscopyJournal of Hip Preservation Surgery · 2026
- Learning Curve Analysis of Dual-Mobility Trapeziometacarpal Arthroplasty: A Single-Surgeon Series With 2-Year Follow-up.The Journal of hand surgery · 2026
- Determining the learning curve for anterolateral supine total hip arthroplasty: a retrospective analysis of six hundred and forty consecutive cases performed by a single surgeon.International orthopaedics · 2026