Development and radiographic evaluation of a normalised guide-pin orientation abacus for anterior closing-wedge tibial osteotomy: Comparison with fixed-ratio and osteotomy-depth methods.
Théo Plassard, Romir Patel, Christophe Jacquet, David Dejour, Antoine Piercecchi, Matthieu Ollivier
Department of Orthopedic Surgery, APHM, CNRS, ISM, Institute of Movement Sciences, Sainte-Marguerite Hospital Aix-Marseille University Marseille France. · Lyon Ortho Clinic Clinique de la Sauvegarde Lyon France.
Key points
From the paper's conclusion- These findings are exploratory and reflect in‐sample performance; independent and clinical validation, including prospective intraoperative testing, are required before the method can be considered accurate, reproducible or ready for intraoperative use.
Abstract
PURPOSE: To develop a simplified mathematical model and abacus estimating anterior wedge resection height during slope-reducing tibial osteotomy from patient-specific guide-pin length and normalised guide-pin orientation, and to evaluate its accuracy under simulated radiographic conditions against fixed-ratio and osteotomy-depth methods. It was hypothesised that normalised guide-pin orientation would provide wedge-height estimates comparable to radiographic planning in both configurations. METHODS: Two hundred fifty-nine calibrated strict lateral knee radiographs from patients undergoing ACL reconstruction were retrospectively analysed in a single-centre radiographic simulation study. Supratuberosity and infratuberosity slope-reducing osteotomies were simulated with a standardised 10° correction, recording guide-pin length, orientation and corresponding anterior wedge height. Three models were compared: a trigonometric model with normalised mean angles, a fixed-ratio model and the osteotomy-depth method. Accuracy (mean absolute error, 90th percentile error) was assessed in-sample against radiographic reference measurements and confirmed by leave-one-out and five-fold cross-validation. RESULTS: Mean guide-pin orientation angles were 67.4° ± 6.0° (supratuberosity) and 110.6° ± 4.7° (infratuberosity). The normalised-angle model produced mean absolute errors of 0.45 ± 0.41 mm (95% CI, 0.40-0.50) and 0.88 ± 0.79 mm (95% CI, 0.78-0.98), with 90th percentile errors of 0.91 and 1.77 mm and Bland-Altman bias of -0.17 and -0.06 mm, lower than both comparator models. Estimation error was not significantly influenced by sex or baseline posterior tibial slope, though the cohort's imbalanced sex distribution (194 men, 65 women) limited power to detect smaller effects in women. CONCLUSION: Within this model-development cohort, a patient-specific abacus based on guide-pin length and normalised guide-pin orientation produced low approximation errors under simulated radiographic conditions, without intraoperative radiographic calibration or complex calculations. These findings are exploratory and reflect in-sample performance; independent and clinical validation, including prospective intraoperative testing, are required before the method can be considered accurate, reproducible or ready for intraoperative use. LEVEL OF EVIDENCE: Level IV, retrospective radiographic simulation/model-development study without clinical outcomes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Complementary roles of standing, supine, and valgus-stress whole-leg radiographs in medial open-wedge high tibial osteotomy planning: supine minimizes bias, whereas standing and valgus-stress reduce outliers.Knee surgery & related research · 2026
- Quantitative Whole-Leg Radiographic Assessment of Coronal Knee-Ankle Alignment: Associations with Talar Inclination and Exploratory Changes After Knee Osteotomy.Diagnostics (Basel, Switzerland) · 2026
- Anteromedial osteotomy and distraction are associated with greater posterior tibial slope increase after medial open-wedge high tibial osteotomy: A retrospective comparison of three techniques.Journal of orthopaedic surgery (Hong Kong) · 2026
- Radiographic medial posterior tibial slope ≥16° predicts multiple revisions after anterior cruciate ligament reconstructionJournal of Experimental Orthopaedics · 2026
- Anteromedial Gap Opening and Osteotomy Sufficiency Are Associated With Multiplanar Correction Errors in Open-Wedge High Tibial Osteotomy: A Computed Tomography-Based Study.Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association · 2026
- Adequately increased postoperative medial proximal tibial angle can prevent medial joint space narrowing after open-wedge high tibial osteotomy: a 3-year cohort study.Knee surgery & related research · 2026