  • Ultrasonographic protocols demonstrate good overall diagnostic accuracy for CIDP and can meaningfully modify disease probability. However, they are best used as adjuncts to clinical and electrodiagnostic assessment rather than as stand-alone confirmatory or exclusionary tests.

Abstract

BACKGROUND: Chronic inflammatory demyelinating polyradiculoneuropathy (CIDP) is a treatable immune-mediated neuropathy for which diagnosis remains challenging because no single biomarker is definitive. Peripheral nerve ultrasonography may provide complementary structural information by detecting nerve enlargement and related morphological abnormalities. We evaluated the diagnostic accuracy of ultrasonographic protocols for CIDP. METHODS: Comprehensive search of MEDLINE/PubMed, Scopus, Embase, Web of Science Core Collection and CENTRAL was conducted from database inception through August 2026 to identify studies evaluating diagnostic accuracy of peripheral nerve ultrasonography in adults with CIDP. Methodological quality was evaluated using the QUADAS-2 tool. Pooled sensitivity and specificity were calculated using a bivariate random-effects model, supplemented by hierarchical summary receiver operating characteristic analysis. Positive and negative likelihood ratios, diagnostic odds ratio, heterogeneity, posttest probabilities, and publication bias were also assessed. RESULTS: Fifteen studies involving 560 reference-positive and 876 reference-negative participants were analyzed. Summary sensitivity and specificity were 0.85 (95% CI 0.78-0.90 and 0.74-0.92, respectively), with AUROC of 0.91 (95% CI 0.89-0.94). Pooled positive and negative likelihood ratios were 5.7 and 0.17, respectively, and the diagnostic odds ratio was 33. At a pretest probability of 39%, a positive result raised the posttest probability to 79%, whereas a negative result lowered it to 10%. Substantial heterogeneity was observed, but threshold effects were minimal. Deeks' test indicated no evidence of publication bias. CONCLUSIONS: Ultrasonographic protocols demonstrate good overall diagnostic accuracy for CIDP and can meaningfully modify disease probability. However, they are best used as adjuncts to clinical and electrodiagnostic assessment rather than as stand-alone confirmatory or exclusionary tests.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Diagnostic Accuracy of Ultrasonographic Protocol for Chronic Inflammatory Demyelinating Polyneuropathy: A Meta-Analysis — Science Skim