Bringing Innovation in Bioequivalence Studies: Evaluating Multiple Test Formulations in a Single Crossover Pivotal Bioequivalence Study Using Multiplicity Correction.
Chandra Teja Uppuluri, Rajkumar Boddu, Sohel Mohammed Khan, Anuj Kumar Saini, Sivacharan Kollipara
Biopharmaceutics Group, Global Clinical Management, Dr. Reddy's Laboratories Ltd., Integrated Product Development Organization (IPDO), Hyderabad, Telangana, India. · Clinical Pharmacokinetics, Global Clinical Management, Dr. Reddy's Laboratories Ltd., Integrated Product Development Organization (IPDO), Hyderabad, Telangana, India.
Key points
From the paper's conclusion- The review provides a practical framework for balancing statistical penalty against the value of preserving the ability to retain more than one formulation candidate within a single pivotal study or development.
Abstract
ICH M13A recognizes higher-order bioequivalence (BE) studies involving multiple test or comparator products. When any one of several test formulations may independently demonstrate BE and support subsequent selection, multiplicity adjustment is required to control the family-wise type I error rate. This requirement introduces a practical penalty through increased sample-size requirements, wider confidence intervals, and a narrower range of test-to-reference geometric mean ratios that would result in BE conclusions. Although the statistical foundations of multiplicity correction are well established, the available literature has focused predominantly on methodological procedures, with limited consideration of the practical questions encountered during pharmaceutical product development. This review briefly summarizes the regulatory and statistical background and presents a scenario-based evaluation of the consequences of multiplicity in multi-formulation crossover BE studies. Analytical assessments were used to quantify sample-size inflation, confidence interval widening, and contraction of the T/R range that would result in a BE conclusion. Simulated BE study datasets complemented these evaluations, analyzed using full-data pooled-MSE (mean squared error) and separate pairwise ANOVA (analysis of variance) approaches and four multiplicity strategies: no adjustment, Bonferroni, Holm, and Hochberg for multiplicity adjustment. The review provides a practical framework for balancing statistical penalty against the value of preserving the ability to retain more than one formulation candidate within a single pivotal study or development. The present evaluation is restricted to non-replicate crossover BE studies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Cautionary Note on Regional Consistency Evaluation With Multiple Primary Endpoints in Multiregional Clinical Trials.Pharmaceutical statistics · 2026
- Advancing Bioequivalence Assessment: A Bayesian Method in the Presence of Non-Lognormality and Extreme Values.Journal of clinical toxicology · 2026
- Parallelism of four-parameter logistic bioassay models: equivalence testing for parameter differences*Journal of Biopharmaceutical Statistics · 2026
- Comparison of multiple testing procedures for clinical trials with two doses and multiple ranked endpoints.Journal of biopharmaceutical statistics · 2026
- Multivariate Analysis of Data From Crossover Clinical Trials.Biometrical journal. Biometrische Zeitschrift · 2026
- Comparison of Metrics for Investigating Bioequivalence in Onset of Action in Incurred Bioequivalence Studies.Pharmaceutics · 2026