Is Geenius HCV Supplemental Assay an Alternative to HCV Confirmatory Western Blot INNO-LIA HCV Score in Repeatedly Reactive Blood Donations After First Line Screening?
Zorana P Kozić, Irina S Maslovarić, Ivana T Drvenica, Marijana V Kovačić, Dragana C Marković, Vesna Lj Ilić, Dušan D Vučetić
Institute for Transfusiology and Haemobiology, Military Medical Academy, Belgrade, Serbia. · Institute for Medical Research, National Institute of Republic of Serbia, University of Belgrade, Belgrade, Serbia.
Key points
From the paper's conclusion- Given the limited number of samples analyzed in this study we can summarize that Geenius HCV Supplemental and Inno-LIA WB assays are comparable pertaining to anti-HCV positive samples, but with discrepancy in results occurring in the area of samples classified with WB assay as indeterminate. However, there is very good agreement between Inno-LIA WB and Geenius ICH positivity/reactivity with individual HCV antigens. Our findings indicate that Geenius ICH Supplemental test cannot replace anti-HCV Inno-LIA WB in confirming anti-HCV antibodies.
Abstract
BACKGROUND: The objective of this study is to evaluate whether the rapid lateral flow immunochromatography Geenius HCV Supplemental Assay (ICH) can serve as an alternative to INNO-LIA HCV Score Confirmatory western blot (WB) assay in a population of blood donors. METHODS: Sera of 60 blood donors, anti-HCV antibodies repeatedly reactive after first line screening with Architect anti-HCV chemiluminescent immunoassay, (ABBOTT, Wiesbaden, Germany) (ICL) were evaluated for anti-HCV antibodies with Geenius HCV Supplemental assay (Bio-Rad. Marnes-la-Coquette-France) (ICH) and Inno-LIA HCV Score (Inogenetics NV. Gent. Belgium) (Inno-LIA WB). The level of agreement between ICH and WB results was determined by kappa statistics. RESULTS: Out of 60 samples identified as anti-HCV antibodies repeatedly reactive by ICL, ICH identified 32% samples as reactive and 2% as indeterminate. WB identified 35% samples as positive and 20% as indeterminate. Kappa analysis detected moderate agreement between ICH and WB in detecting anti-HCV antibodies (kappa = 0.60). Moderate to almost very good agreement is acknowledged between ICH and WB in reactivity with individual HCV antigens. CONCLUSION: Given the limited number of samples analyzed in this study we can summarize that Geenius HCV Supplemental and Inno-LIA WB assays are comparable pertaining to anti-HCV positive samples, but with discrepancy in results occurring in the area of samples classified with WB assay as indeterminate. However, there is very good agreement between Inno-LIA WB and Geenius ICH positivity/reactivity with individual HCV antigens. Our findings indicate that Geenius ICH Supplemental test cannot replace anti-HCV Inno-LIA WB in confirming anti-HCV antibodies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Clinical Performance of the Elecsys HCV Duo Immunoassay Compared with a Standard-of-Care Algorithm Using Alinity Anti-HCV Screening and HCV RNA Confirmation.Diagnostics (Basel, Switzerland) · 2026
- Anti-HIV Serological Profiles and Concordance of Chemiluminescent Immunoassay Screening With a Supplemental Rapid Test Among Blood Donors in Côte d'Ivoire.Journal of immunology research · 2026
- B-192 Clinical performance evaluation of Elecsys HCV Duo immunoassay for simultaneous detection of HCV Core antigen and anti-HCV antibodies in Korean populationClinical Chemistry · 2026
- Evaluation of a Rapid Confirmatory Human Immunodeficiency Virus Test: Overall Performance and Band Analysis.Clinical laboratory · 2026
- Diagnostic performance and clinical utility of an HCV antigen-antibody combination assay across diverse real-world cohorts.Journal of clinical microbiology · 2026
- Revisiting Anti-HCV Seropositivity: Signal Intensity, Diagnostic Uncertainty, and the Limitations of Fixed Cut-Offs.Diagnostics (Basel, Switzerland) · 2026