CO and NO Detection by MN4@SWCNT in Background Gases: Multiscale DFT, Microkinetic, Boltzmann Transport Study.
Adhitya Gandaryus Saputro, Ira Puspitasari, Dicky Setianto, Farrel Dzaudan Naufal, Imran Shakir, Chin-Sung Hsiao, Febdian Rusydi
Quantum and Nano Technology Research Group, Bandung Institute of Technology, Bandung, Indonesia. · Information Systems Study Program, Faculty of Science and Technology, Universitas Airlangga, Surabaya, Indonesia.
Key points
From the paper's conclusion- Our results show that the CuN4@SWCNT system emerges as the optimal candidate for CO detection within the 1-105 ppm working range.
Abstract
Detecting hazardous gases like CO and NO at room temperature is vital for environmental and health monitoring. While single-walled carbon nanotubes (SWCNTs) are a potential material for a room-temperature sensor, their pristine forms exhibit very weak adsorption toward CO and NO gases. This study investigates the sensing performance of SWCNTs embedded with transition metal-nitrogen (MN4) active sites (M = Mn, Fe Co, Ni, Cu). These active sites are known for their ability to properly bind small gases in various catalytic applications. By combining density functional calculations, microkinetic simulations, and Boltzmann conductivity calculations, we account for atmospheric background gases to provide a realistic evaluation of sensor selectivity and response. Our findings indicate that relative adsorption energies govern surface coverage, while changes in conductivity correlate with the density of states near the Fermi level. Our results show that the CuN4@SWCNT system emerges as the optimal candidate for CO detection within the 1-105 ppm working range. The NiN4@SWCNT system is also viable for CO detection in this range, provided that interfering species such as NO and NO2 are absent. For NO detection, the NiN4@SWCNT system is identified as the best performer, operating effectively in the ultra-low concentration range (~0.01-100 ppb) with high selectivity. This work also elucidates the fundamental trade-off between adsorption strength and recovery time, offering a robust theoretical framework for designing highly selective and reversible gas sensors relevant to health risk monitoring and early warning applications.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Performance comparison of CTAB-modified NiO, ZnO, and SnO2 sensors for CO and CH4 detection in environmental and health applicationsScientific Reports · 2025
- Enhanced Room Temperature NO2 Detection by Carbon Nanofibers and Single-Walled Carbon Nanotubes: Experimental and Molecular DynamicsChemosensors · 2025
- Enhanced Gas Sensitivity Based on CNTs@SnO2@ZIF-67 Composite Materials for an NO2 Gas Sensor at Room Temperature.ACS omega · 2026
- Tailored ZnCu Conductive MOF as a Floating-Gate in Carbon Nanotube Network FET NH₃ SensorsACS Sensors · 2025
- PdPt Bimetallic Nanoparticle-Modified Sb-Doped SnO2/SiO x for Enhanced and Stable CO SensingACS Applied Nano Materials · 2026
- Role of Transition-Metal Centers in the Capture and Activation of Toxic and Greenhouse Gases on ZnO Nanoclusters: A DFT StudyMaterials Research Express · 2026