Journal of clinical apheresis

Apheresis in Children of Weight Under 7 kg-A Single Center Experience.

Phassawan Rungsiprakarn, Bryan E Wilson, Natalie E Rintoul, K Taylor Wild, David F Friedman

Department of Pathology & Laboratory Medicine, Children's Hospital of Philadelphia, Philadelphia, Pennsylvania, USA. · Department of Apheresis, Children's Hospital of Philadelphia, Philadelphia, Pennsylvania, USA.

Key points

From the paper's conclusion
  • We reviewed 68 procedures performed in 19 children weighing less than 7 kg, including hematopoietic progenitor and T-cell collections and plasmapheresis.

Abstract

Although apheresis techniques in children are well established, published experience with very low-weight children is limited. We reviewed 68 procedures performed in 19 children weighing less than 7 kg, including hematopoietic progenitor and T-cell collections and plasmapheresis. With significant modifications of standard techniques, all but one procedure was successfully and safely completed without serious citrate toxicity. Access was a major challenge. For plasmapheresis, the mean plasma volume removed was 1.2 × total plasma volume, but the mean total blood processed was 1.74 × total blood volume (TBV). For collections, the mean number of whole blood volumes processed was 4.1 × TBV. For T cell collections, the median CD3+ yield was 243.6 × 106/kg. For HPC collections, the median CD34+ cell yield was 14.8 × 106/kg. Mean durations for collections and plasmapheresis were 247.00 and 120.67 min, respectively. Of the CBC parameters, only platelet count was significantly lower after collections.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Apheresis in Children of Weight Under 7 kg-A Single Center Experience — Science Skim