Design and Usability Evaluation of a Patient-Specific 3D-printed PLA Wrist Cast Intended for Distal Radius Fracture Immobilization.
Devanshi Derashri, Abhishek Agarwal, Gauri Gujral, Ira Tyagi, Vishal Srivastava, Atul Sharma, Vishal Gupta
Department of Biomedical Engineering Thapar Institute of Engineering and Technology Patiala India. · Department of Mechanical Engineering, College of Science and Technology Royal University of Bhutan Phuentsholing Bhutan.
Key points
From the paper's conclusion- This study aimed to design and evaluate a patient‐specific 3D‐printed polylactic acid wrist cast for conservative immobilization of distal radius fractures.
Abstract
BACKGROUND AND AIMS: Distal radius fractures require effective immobilization to ensure proper healing and functional recovery. Conventional plaster of Paris casts are associated with limitations including poor ventilation, hygiene concerns, and patient discomfort. This study aimed to design and evaluate a patient-specific 3D-printed polylactic acid wrist cast for conservative immobilization of distal radius fractures. METHODS: A customized lattice-structured wrist cast was designed using anthropometric measurements and fabricated by fused deposition modelling. A prospective prototype usability evaluation was conducted between January and July 2025 in 50 healthy volunteers, who wore the customized cast on the non-fractured upper limb for short-term assessment. Physical fit, comfort, ease of use, perceived stability, and overall acceptance were evaluated using a structured usability questionnaire. RESULTS: The fabricated casts had a mean mass of approximately 160 g. Forty-four of 50 participants (88%) reported high overall satisfaction. Participants reported favourable physical fit, comfort, usability, and perceived stability during short-term wear. Minor, transient skin irritation was reported by 5 of 50 participants (10%; 95% CI, 4.3%-21.4%), with no serious adverse events observed during the evaluation period. CONCLUSION: The prototype demonstrated favourable short-term usability and participant acceptance in healthy volunteers. The findings provide preliminary evidence supporting further evaluation of the patient-specific PLA cast in patients with distal radius fractures. Clinical effectiveness, fracture stability, biomechanical performance, and long-term safety require evaluation in appropriately designed clinical studies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Pedicled Radial Artery Perforator Flaps for Reconstruction of the Upper Limb: A Systematic Review and Meta‐Analysis of Single‐Arm StudiesMicrosurgery · 2026
- Industrial Plasticine-Assisted Physical-Model Reconstruction Versus Virtual Surgical Planning for Comminuted Le Fort I Fractures: A Retrospective Cohort Study.The Journal of craniofacial surgery · 2026
- Comparison of Direct 3D Scans and Plaster Casts in Digital Ankle-Foot Orthosis Workflows.Medical sciences (Basel, Switzerland) · 2026
- Design and Fitting Performance of a 3D-Printed Personalized Upper-Limb Socket: A Comparative Case Report.Sensors (Basel, Switzerland) · 2026
- 3D-Printed PLA/PETG Sterilizable Static/Dynamic Modular External Finger Fracture Fixator.Bioengineering (Basel, Switzerland) · 2026
- Computational analysis of Lattice-Integrated transfemoral prosthetic socketsMaterials & Design · 2026