Spirometric Lung Function Among Rice Mill Workers in Sylhet District, Bangladesh: A Cross-Sectional Study.
Pankaj Kanti Goswami, Porimol Debnath, Yeasmin Jui, Ishrat Jahan Jannat, Md Shihab Mostafa, Md Sabbir Hossain
Department of Physiology Sylhet MAG Osmani Medical College Sylhet Bangadesh. · University of Manitoba Winnipeg Manitoba Canada.
Key points
From the paper's conclusion- Longer employment duration was associated with a modestly lower measured FEV 1 /FVC and percent‐predicted FVC, but the cross‐sectional design, lack of direct exposure assessment, and absence of a control group preclude causal attribution to rice dust.
Abstract
BACKGROUND: Rice mill workers may encounter respiratory hazards, but a spirometric survey without direct dust measurements or an unexposed comparison group cannot establish an exposure-response relationship. This study described measured spirometric patterns and examined associations of lung function with employment duration, smoking, age, height, and body mass index among rice mill workers in Sylhet District. METHOD: This cross-sectional study analyzed 203 male workers recruited through cluster sampling in 2024. Lung function was assessed with an RMS Helios 401 spirometer. Study records indicated that at least three acceptable maneuvers were obtained and the best value was retained. Descriptive statistics, one-way analysis of variance, and multivariable linear regression were used. Regression models used measured FVC, measured FEV1, and measured FEV1/FVC as primary outcomes, modeled employment duration continuously, omitted weight when BMI was included, and used HC3 robust standard errors. RESULT: Among 203 analyzed workers, 169 (83.25%) were normal by the study's legacy fixed thresholds, 31 (15.27%) had low FVC with a preserved measured FEV1/FVC ratio (a possible restrictive pattern), one (0.49%) had an obstructive spirometric pattern, and two (0.99%) had both a low ratio and low FVC. Reduced FEF25-75 (<70% predicted) occurred in 68 (33.50%) workers but was treated as a variable flow measure rather than a diagnosis. In adjusted models, each additional employment year was associated with a 0.21-percentage-point lower measured FEV1/FVC (β = -0.211, 95% CI -0.415 to -0.007; p = 0.043), but not with measured FVC or FEV1. A sensitivity model showed lower percent-predicted FVC with longer employment (β = -0.537 percentage points/year, 95% CI -0.988 to -0.086; p = 0.020). CONCLUSION: Most workers had spirometry within the study's fixed thresholds. Longer employment duration was associated with a modestly lower measured FEV1/FVC and percent-predicted FVC, but the cross-sectional design, lack of direct exposure assessment, and absence of a control group preclude causal attribution to rice dust. Low FVC requires lung-volume testing before restriction can be confirmed.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Respiratory Morbidity among Jute Mill Workers: A Cross-Sectional Study in a Selected Jute Mill of West Bengal 2024-2025.Indian journal of occupational and environmental medicine · 2026
- Pulmonary Function Impairment From Occupational Particulate Exposure Among Informal Sector Workers in South Asia: A Systematic Review and Meta-Analysis.American journal of industrial medicine · 2026
- Chronic respiratory symptoms and associated factors among furniture and bamboo production workers in Northwest Ethiopia: a cross-sectional studyBMC Public Health · 2026
- Lung Function Disorders among Informal Workers at Urban Final Disposal Facilities for Solid WasteBIO Web of Conferences · 2026
- Spirometric Lung Function Patterns Across Body Mass Index Categories in Ghana: A Tertiary Care Perspective.Pulmonary medicine · 2026
- Association of Age, Gender, Smoking Status, and Hemoglobin Levels with VO 2 max among Roofers: A Cross-Sectional StudyBIO Web of Conferences · 2026