From the paper's conclusion
  • These results demonstrate the technical feasibility of the assessed AMP/PZ configuration for refinery‐scale CO 2 capture at an efficiency above 90%, whereas the economic findings should be interpreted in the context of the assumptions and limitations of the comparative assessment.

Abstract

The use of blended amine solvents for carbon capture has emerged as a promising alternative to conventional monoethanolamine (MEA) due to their lower regeneration energy and improved thermodynamic performance. In this study, a pilot‐validated techno‐economic evaluation is conducted for an aqueous solvent blend containing 28 wt% 2‐amino‐2‐methyl‐1‐propanol (AMP) and 17 wt% piperazine (PZ), with performance benchmarked against the conventional 30 wt% MEA process. AMP/H 2 O and PZ/H 2 O thermodynamic parameters were regressed from literature using vapor–liquid equilibrium data and implemented in a rate‐based Aspen Plus V14 model with established reaction kinetics. The simulation was validated against pilot plant data, showing average deviations of 4.39% for capture efficiency, solvent loading, and reboiler duty. The validated model was applied to a refinery power plant producing 434 MWe, treating a flue gas stream of 212,600 kg h −1 containing 12.74 mol% CO 2 . At 91.28% capture efficiency, optimal performance was achieved at a liquid‐to‐gas ratio of approximately 2.6 and a stripper pressure of 2.2 bar. The AMP/PZ system achieved a specific reboiler duty of 3.57 GJ t −1 CO 2 , slightly lower than 3.61 GJ t −1 CO 2 for MEA. The economic assessment estimates a capital cost of $49.69 million and annual operating costs of $24.04 million, resulting in a CO 2 avoidance cost of $95.13 t −1 CO 2 . Compared with the published MEA benchmark ($163.05 t −1 CO 2 ), the proposed AMP/PZ process exhibited lower estimated avoidance cost under the respective process configurations and economic assumptions. These results demonstrate the technical feasibility of the assessed AMP/PZ configuration for refinery‐scale CO 2 capture at an efficiency above 90%, whereas the economic findings should be interpreted in the context of the assumptions and limitations of the comparative assessment.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Techno‐Economic Assessment of AMP/PZ Solvent for Industrial‐Scale CO 2 Capture From a Refinery Power Plant — Science Skim