A Dual‐Mode Triple‐Signal Flexible Pressure Sensor Based on Laser‐Induced Graphene
Jianing Zhang, Deng Wang, Peilong Li, Zhe Liu, Ruyu Zhang, Bowen Lu, Feng Liu
Key points
From the paper's conclusion- Herein, to improve the mechanical reliability of flexible pressure sensors, a strategy based on signal redundancy and the complementary integration of piezocapacitive and piezoresistive sensing modes was used to implement a dual‐mode triple‐signal flexible pressure sensor.
Abstract
Mechanical reliability is crucial for the application of flexible sensors that are frequently subjected to bending. Herein, to improve the mechanical reliability of flexible pressure sensors, a strategy based on signal redundancy and the complementary integration of piezocapacitive and piezoresistive sensing modes was used to implement a dual‐mode triple‐signal flexible pressure sensor. The sensor consists of a pair of interdigital electrodes, an Ecoflex elastomer loaded with a laser‐induced graphene (LIG) layer, and a bottom electrode. Under external pressure, the resistive channel formed by the interdigital electrodes and LIG layer generates a piezoresistive signal, whereas two capacitive channels formed by the interdigital electrodes, elastomer, and bottom electrode generate two piezocapacitive signals. Therefore, the sensor has two redundant signals, which obviously improves its mechanical reliability. Moreover, the sensor can operate in both piezocapacitive and piezoresistive modes simultaneously, which is beneficial for improving its overall performance through mode complementarity. In the piezocapacitive mode, the sensor exhibits sensitivities of 0.1602 kPa −1 and 0.1548 kPa −1 with response/recovery times of 92/128 ms and 76/114 ms, respectively. In the piezoresistive mode, the sensor has a high sensitivity of 38.64 kPa −1 with a response/recovery time of 100/83 ms. Furthermore, the sensor maintained reliable signal outputs after more than 4000 loading cycles, demonstrating excellent durability. The application in human motion monitoring shows that the sensor can effectively detect physiological signals while maintaining a consistent response of the three output channels. This work provides a new strategy for improving the mechanical reliability of flexible pressure sensors through multisignal redundancy design and mode complementarity.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Laser‐Induced Graphene for Pressure and Strain Sensors: Fabrication, Performance Optimization, and ApplicationsSmall · 2026
- Temperature-compensated gradient-porosity laser-induced graphene pressure sensor overcomes sensitivity-range trade-off for wearable heartbeat monitoringChemical Engineering Journal · 2026
- Highly Sensitive and Waterproof Flexible Sensor Based on Liquid Metal/Laser-Induced Graphene Multilayer Structure for Human Signal DetectionLangmuir · 2026
- Flexible, Low-Cost, and High-Performance Capacitive Pressure Sensor Enabled by Combining Double-Sided Microstructured Electrodes with a Single Soft Dielectric LayerACS Applied Electronic Materials · 2026
- In-Situ Controllable Fabrication and Performance of Laser-Induced Graphene Flexible Sensors for Human Motion Monitoring.Sensors (Basel, Switzerland) · 2026
- A Quasi-homogeneous-Integrated Flexible Proximity-Pressure Dual-Mode Sensor for Human Machine InteractionACS Applied Materials & Interfaces · 2026