Seismic Isolation Retrofit Following Early Design Standards: A Case Study
Ricardo Bustamante, Gilberto Mosqueda, Kayla Erler, Claudio Sepulveda, Maikol Del Carpio, Joshua Lopez, Kenneth J. Elwood
Key points
From the paper's conclusion- To examine early retrofit applications, a seismic performance assessment is conducted on a historical building retrofitted with base isolation in the early 1990s.
Abstract
Seismic isolation has been widely applied especially for the design of new essential structures and for retrofit of historical buildings in high seismic risk regions. For new designs, the isolated superstructure is designed to remain essentially elastic for the considered seismic hazard, providing limited damage compared to conventional fixed‐based structures. Similarly, retrofit applications aim to limit superstructure base shear below the yield capacity. Notably, design standards for seismic isolation have evolved toward stricter requirements in recent years. To examine early retrofit applications, a seismic performance assessment is conducted on a historical building retrofitted with base isolation in the early 1990s. The structure is examined using current seismic evaluation and design requirements for seismically isolated structures and found to require further assessment. Modifications limited to the isolation system are explored by examining the feasible domain of the isolation system properties that provide adequate performance, while considering the nonlinear superstructure response, moat wall pounding, and variability in isolation system behavior through property modification factors. Improved performance is achieved by increasing the effective isolation period to reduce demands on the superstructure combined with supplemental damping to maintain reasonable isolation system displacements. Supplemental viscous damping below 15% of critical and the use of nonlinear viscous dampers with a velocity exponent α ≥ 0.7 are found to be most effective. The framework presented in this study provides a useful tool for evaluation of retrofit design alternatives considering simplified nonlinear models and considering a balance between the superstructure base shear capacity and the isolation system displacement capacity.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Earthquake-Resistant Structural Design and Retrofitting Technologies: A Systematic Review of Performance Materials and Resilience OutcomesBuildings · 2026
- Application of Viscoelastic Dampers for Seismic Retrofitting of Existing Reinforced Concrete BuildingsBuildings · 2026
- Effects of the coupling damping term on seismic responses of base-isolated structuresJournal of Physics: Conference Series · 2026
- Structural Control for the Seismic Protection of Cultural Heritage: State of the Art and Review of Full-Scale ApplicationsHeritage · 2026
- Seismic Review of Retrofit Effect by Base Isolation of Load Center Cabinet in Operating Nuclear PlantsApplied Sciences · 2026
- Seismic performance assessment of inerter-based damping systems for structural vibration control – a comprehensive reviewFrontiers in Built Environment · 2026