Integrated High‐Fidelity Soil–Structure‐Interaction Analysis of a Tall Reinforced Concrete Core Wall Building
Kristijan Kolozvari, Ryutaro Kadota, Andres Reyes, Satoru Ikeda, Mahdi Taiebat, Farzad Naeim, Masayoshi Nakashima
Key points
From the paper's conclusion- These findings indicate that fixed‐base modeling remains adequate for PBSD on shallow, relatively stiff soil sites, though SSI may warrant explicit consideration for low‐ to mid‐rise buildings, deeper or softer soil profiles, or design checks at or below ground level.
Abstract
This paper evaluates the influence of soil–structure interaction (SSI) on the seismic performance of a 25‐story reinforced concrete core wall building designed under performance‐based seismic design (PBSD) guidelines. A high‐fidelity three‐dimensional nonlinear finite element model was developed in OpenSees to capture nonlinear soil and superstructure behavior and explicit interaction among the superstructure, foundation, and surrounding soil. Nonlinear response‐history analyses were conducted for both the SSI model and a conventional fixed‐base superstructure model. Engineering demand parameters, including interstory drifts, floor accelerations, coupling beam rotations, wall strains, and core wall shear and moment demands, were compared to assess SSI effects. Results show that the two models produce broadly consistent predictions of seismic demands above ground level. The SSI model predicted up to 50% smaller shear force in basement walls due to interaction between the basement walls and surrounding soil. SSI primarily reduced short‐period floor acceleration spectra (<0.5 s) at the floor center of mass and localized demands at the ground level, where shear and moment responses in the reinforced concrete (RC) core differed by up to 10%. Moment demands imposed on the foundation were also reduced in the SSI model by up to approximately 10% and 20% beneath the RC core and basement walls, respectively. This relatively limited SSI influence is mainly attributed to the site's stiff conditions, where excavation of about 20 m of softer soils left a dense coarse‐grained layer ( V s ≈ 480 m/s) over bedrock at 30 m depth, resulting in a short site period and limited soil–foundation compliance. These findings indicate that fixed‐base modeling remains adequate for PBSD on shallow, relatively stiff soil sites, though SSI may warrant explicit consideration for low‐ to mid‐rise buildings, deeper or softer soil profiles, or design checks at or below ground level.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparative evaluation of load transfer and coupling techniques for soil–structure interaction in 3D building modelsScientific Reports · 2026
- Influence of soil-structure interaction and ground motion parameters on the seismic vulnerability of RC buildingsScientific Reports · 2026
- Reassessing the Comparative Effectiveness of Masonry Infill Retrofit Layouts Under Soil–Structure Interaction in Existing RC FramesApplied Sciences · 2026
- Concept for Consistent Soil–Structure Interaction Regarding Structural AnalysisBuildings · 2026
- Sensitivity of Soil-Structure Interaction to bridge pier height: A numerical study of fixed-base and SSI modelsE3S Web of Conferences · 2026
- Seismic performance and mitigation strategies for soil-foundation-structure systems on liquefiable soilsResults in Engineering · 2026