Energy Science & Engineering

Investigation of the Rotor‐Stator Interaction on the Energy Loss in Pump Working Conditions of Bulb Turbine Unit for Tidal Power Stations

Longyue Sun, Zhaoyu Lv, Naijiang Xu, Qiang Pan, Desheng Zhang, Xavier Escaler

Key points

From the paper's conclusion
  • The time‐frequency characteristics of power loss in the energy balance equation reveals that under steady flow rate conditions, the power loss in the rib is mainly caused by the RSI between the rib and the impeller, the power loss in the impeller is affected by the impeller rotation and the number of ribs, while the power loss in the diffuser is mainly affected by the impeller rotation, and the do

Abstract

To improve the performance of large bulb turbine unit at pump working conditions, it is important to identify the primary sources of power loss. In this study, the power loss in the various flow rate conditions of a reduced scale model have been numerically investigated based on the energy balance equation and the pressure fluctuations solving the transient flow with the SST k‐ω turbulence model in order to characterize the effects of the rotor‐stator interaction (RSI). The numerical model has been validated comparing the predicted unit performance with experimental results showing a good agreement. The power loss in the rib, impeller and diffuser domains present the same trends as the total pressure loss. Moreover, the most significant sources of power loss are associated with the Reynolds stress and wall friction. The energy balance equation has permitted to identify the typical vortex structures in the regions with larger power loss. The time‐frequency characteristics of power loss in the energy balance equation reveals that under steady flow rate conditions, the power loss in the rib is mainly caused by the RSI between the rib and the impeller, the power loss in the impeller is affected by the impeller rotation and the number of ribs, while the power loss in the diffuser is mainly affected by the impeller rotation, and the dominant frequency of power loss is 1 f r or 4 f r . At the same time, it is found that the power loss of each sub‐item only fluctuates within a small range over time. The pressure fluctuation characteristics of the monitoring points at the rotor‐stator interface also verify the power loss characteristics of the flow field.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Investigation of the Rotor‐Stator Interaction on the Energy Loss in Pump Working Conditions of Bulb Turbine Unit for Tidal Power Stations — Science Skim