Epilepsia

Intrarater reliability of expert electroencephalographic interpretation of 100 full-length recordings.

Doyle Yuan, Irfan S Sheikh, Roohi Katyal, Peter W Kaplan, Neel Fotedar, Jordan Clay, Selim Benbadis, Sindhu Richards,

Department of Neurology, University of Texas Southwestern Medical Center, Dallas, Texas, USA. · Department of Neurology, Louisiana State University Health Sciences Center, Shreveport, Louisiana, USA.

Key points

From the paper's conclusion
  • We found generally strong within-expert agreement in EEG interpretation, especially in the identification of epileptiform abnormalities. Nevertheless, the number of flipped decisions was high enough to be clinically consequential. This undesired variability ("occasion noise") may be addressed by interventions to (1) decrease this noise directly and (2) reduce case ambiguity with longer recordings and better EEG data whenever feasible.

Abstract

OBJECTIVE: The value of electroencephalography (EEG) relies on accurate and reliable interpretation. Prior research has demonstrated imperfect interrater reliability, but intrarater reliability remains poorly characterized. We performed a "noise audit" primarily to measure intrarater variability in EEG interpretation by epileptologists. METHODS: Experts independently rated the same 100 full-length EEGs on two separate occasions ≥60 days apart, unaware the EEGs were the same. EEGs were recorded from adult (56%) and pediatric patients in outpatient (78%) and non-critical care inpatient settings. There were 20 studies in each of five categories: normal, focal epileptiform (FE), generalized epileptiform (GE), focal nonepileptiform (FNE), and generalized nonepileptiform (GNE) abnormalities. EEGs were presented using our online platform (EEGHub) without clinical information except for age and sex. Experts rated each recording and indicated their level of confidence (LOC) for each EEG and overall. We analyzed percent as well as chance-corrected intra- and interrater agreement. RESULTS: Fourteen experts (mean of 19 years EEG reading experience, range = 4-52 years) were included in the study. Percent self-agreement was 96% for GE, 90% for FE, 88% for FNE, and 87% for GNE abnormalities; 90% for any epileptiform abnormality; and 82% for any nonepileptiform abnormality. Self-agreement was strongly correlated with interrater agreement (mean κML), which was almost perfect for GE (.90, 95% confidence interval [CI] = .87-.94) and FE (.82, 95% CI = .77-.87) and substantial for GNE (.75, 95% CI = .69-.81) and FNE (.74, 95% CI = .68-.80) abnormalities. LOC correlated with self-agreement on the presence of nonepileptiform but not epileptiform abnormalities. SIGNIFICANCE: We found generally strong within-expert agreement in EEG interpretation, especially in the identification of epileptiform abnormalities. Nevertheless, the number of flipped decisions was high enough to be clinically consequential. This undesired variability ("occasion noise") may be addressed by interventions to (1) decrease this noise directly and (2) reduce case ambiguity with longer recordings and better EEG data whenever feasible.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Intrarater reliability of expert electroencephalographic interpretation of 100 full-length recordings — Science Skim