Environmental Progress & Sustainable Energy

Probabilistic cradle‐to‐gate carbon footprint of e‐methanol under coupled electricity and CO 2 ‐source conditions: Comparison with published projects and an industrial‐park application

Yuqing Liu, Jieyi Li, Hao Zhou, Jingjing Zhan

Key points

From the paper's conclusion
  • These results identify electricity intensity, CO 2 supply and heat integration as key variables for early‐stage screening.

Abstract

Electricity supply, CO 2 sourcing and process heat determine whether e‐methanol has a lower cradle‐to‐gate carbon footprint than fossil methanol. We developed a screening model for 1 kg methanol and propagated uncertainty in four foreground parameters using Monte Carlo analysis. Against a natural‐gas‐methanol reference of 0.944 kg CO 2 e per kg of methanol, median break‐even electricity factors were 0.075 and 0.053 kg CO 2 e/kWh for high‐concentration and point‐source CO 2 , with fifth‐percentile (P5) thresholds of 0.069 and 0.048. Sampling residual heat over 0–4 MJ per kg of methanol lowered the point‐source P5 threshold to 0.033. For the high‐temperature direct‐air‐capture route, adding an illustrative U.S.‐average upstream natural‐gas burden lowered the break‐even factor from 0.027 to 0.018 kg CO 2 e/kWh. In the 100,000 t/y park case, the 97% wind‐equivalent, 100‐km point‐source configuration had a footprint of 0.921 kg CO 2 e per kg of methanol; lower capture‐heat efficiency reversed its small advantage over the reference. These results identify electricity intensity, CO 2 supply and heat integration as key variables for early‐stage screening.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Probabilistic cradle‐to‐gate carbon footprint of e‐methanol under coupled electricity and CO 2 ‐source conditions: Comparison with published projects and an industrial‐park application — Science Skim