Design and performance of hybrid thermal energy storage integrated within a solar‐powered vapor absorption cooling system for milk chilling
Dinesh Kumar Sharma, Dilip Sharma, Manu Augustine, Vishnu Agrawal, Ahmed Hamza H. Ali
Key points
From the paper's conclusion- This study presents the design, performance, productivity, cost performance, and environmental impact of a 400 MJ hybrid sensible and latent thermal energy storage (comprising Xylitol as a phase change material and soft water as a heat transfer fluid) when integrated within a system that has a 17.5 kW single‐effect LiBr‐H 2 O vapor absorption driven by a hot water outlet from an 81 m 2 solar colle
Abstract
Solar‐powered sorption cooling systems inevitably require optimized thermal energy storage to achieve consistent performance and economic viability, thereby ensuring sustainability. This study presents the design, performance, productivity, cost performance, and environmental impact of a 400 MJ hybrid sensible and latent thermal energy storage (comprising Xylitol as a phase change material and soft water as a heat transfer fluid) when integrated within a system that has a 17.5 kW single‐effect LiBr‐H 2 O vapor absorption driven by a hot water outlet from an 81 m 2 solar collector field used for cooling 1000 L of milk per day. The dynamic modeling of the entire system as a function of time is performed, along with the integration of a hybrid thermal energy storage system, using fundamental and empirical relations. Furthermore, a year‐round analysis is conducted to estimate the amount of cold energy produced and the overall system performance. The results clearly show that the system can produce up to 28,360 kWh of cold energy annually, thereby reducing annual CO 2 emissions by 2.98 tonnes in the Indian context. The economics of cooling produced with this system have been improved investigated with carbon credit‐linked incentives, which resulted in the simple and discounted payback periods of 8.9 and 12.23 years, respectively. The levelized cost of cooling of 0.103 $/kWhc has been achieved for the system, with an internal rate of return of 15.4%.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Energy, economic, and environmental (3E) analysis of biogas generators waste heat recovery for sustainable cooling applications in wastewater treatment plantsInternational Journal of Thermofluids · 2026
- Performance assessment of hybrid sensible–latent thermal energy storage for medium-temperature applicationsJournal of Physics: Conference Series · 2026
- Experimental and thermodynamic investigation of a solar‐assisted lithium bromide–water single‐effect absorption cooling system with a flat‐plate collector: Energy, exergy, and thermo‐economic analysisEnvironmental Progress & Sustainable Energy · 2026
- Multi-Fidelity Modelling of Solar-Driven Hybrid Cooling Panels with Waste Cooking Oil as Phase Change MaterialsResults in Engineering · 2026
- Innovative combination of optimization and energy management strategies for integrated cooling, heating and power systems with ice thermal energy storageJournal of Energy Storage · 2026
- Smart-Farm-Integrated Cold Thermal Energy Storage (CTES) Systems for Clean, Solar-Powered Rural Postharvest Cooling: A ReviewClean Technologies · 2026