Multiphysics Modeling of Metronidazole Electroreduction at Polypyrrole/ ZIF ‐67 Porous Electrodes: Linking Porosity, Transport, and Kinetics
Rima Heider Al Omari, G. Padma Priya, Subhashree Ray, Talal Aziz Qassem, Gunjan Garg, Renu Sharma, Zokir Ataullaev, Rasul Usmanov,
Key points
From the paper's conclusion- This study investigates MNZ electroreduction at polypyrrole (PPy) nanotube/ZIF‐67‐modified electrodes using a two‐dimensional axisymmetric multiphysics framework incorporating transient diffusion, porous‐medium transport, and concentration‐dependent cathodic kinetics.
Abstract
Understanding the coupling between porous architecture, molecular transport, and interfacial kinetics is essential for improving metronidazole (MNZ) electrochemical detection. This study investigates MNZ electroreduction at polypyrrole (PPy) nanotube/ZIF‐67‐modified electrodes using a two‐dimensional axisymmetric multiphysics framework incorporating transient diffusion, porous‐medium transport, and concentration‐dependent cathodic kinetics. The effective‐medium description incorporates accessible porosity and tortuosity, yielding a prescribed diffusivity dependence of D eff ∝ ε 2.5 . Porosity was varied from 0.2 to 0.8 to examine transport–reaction interactions under controlled operating conditions. The corrected analytical limiting‐current formulation predicts a 32‐fold increase in geometrically normalized current density across this interval, distinguishing constitutive transport scaling from coupled numerical behavior. Kinetic parameterization employed an effective charge‐transfer coefficient of 0.48 and reference exchange‐current densities within (0.8–1.4) × 10 −6 A cm −2 . Concentration‐dependent experimental comparisons were organized into calibration and validation conditions, with a reported maximum normalized root mean square error of 0.072. Sensitivity analysis identified porosity as the most influential parameter near the reference operating state, while finite perturbations revealed stronger interval‐dependent responses. The detection‐limit analysis was formulated using calibration sensitivity and a prescribed baseline‐noise standard deviation of 0.1 nA, providing conditional theoretical estimates rather than independently validated analytical detection limits. The findings establish a physically interpretable framework for assessing porous‐layer transport resistance, interfacial reactant availability, and potential‐dependent kinetic limitations in PPy/ZIF‐67‐based electrochemical sensing.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Synergistic Experimental and Computational Approach to the Design of MIPs Targeting Metronidazole.Analytical chemistry · 2026
- Electrochemical sensor based on α-Fe2O3/rGO core-enhanced carbon interfaces for ultra-sensitive metronidazole detectionScientific Reports · 2025
- Engineering d-p orbital hybridization promotes active hydrogen desorption for sensitive electrochemical detection of metronidazole in environmental resources.Environmental research · 2026
- Ni-Metal–Organic Framework/β-Cyclodextrin/Functionalized Carbon Black Nanomaterials for Enhanced Electrochemical Sensing of Metronidazole in Environmental and Clinical SamplesACS Applied Nano Materials · 2025
- Hierarchical Ni-rGO nanocomposite derived from e-waste graphite for trace-level electrochemical sensing of metronidazole.RSC advances · 2026
- Pore Geometry and Nitrogen Doping Regulate Carbon-Source Transport Through Carbon Nanocage Shells for CO2 Electroreduction.Nanomaterials (Basel, Switzerland) · 2026