Chiral Ionic Covalent Organic Framework Core-Shell Composite Material CD-COF-Li@SiO2 for HPLC Enantioseparation.
Chang-Xiu Ma, Hong-Mei Zhou, Fu Li, Jin Liu, Xiao-Fang Shu, Peng-Bo Du, Sheng-Ming Xie, Kun-Ming Jiang,
Yunnan Key Laboratory of Modern Separation Analysis and Substance Transformation, College of Chemistry and Chemical Engineering, Yunnan Normal University, Kunming, P.R. China.
Key points
From the paper's conclusion- In addition, the proposed CD-COF-Li@SiO2-based HPLC method demonstrated favorable performance for quantitative analysis by using (S)-ethyl mandelate as a model analyte.
Abstract
Ionic covalent organic frameworks (iCOFs), as a branch of emerging organic framework materials, integrate charged functional sites with periodically ordered pore structures. Owing to their distinctive merits, including adjustable electrostatic interactions, permanent porosity, well-defined pore channels, and excellent structural designability, iCOFs have aroused widespread research interest. In this study, a novel HPLC chiral stationary phase (CD-COF-Li@SiO2) was prepared by an in situ growth strategy. The CD-COF-Li@SiO2 column showed good chiral separation performance for 19 pairs of enantiomers, including alcohols, esters, ketones, organic acids, and aldehydes. Most of the analytes were baseline-separated, and the resolution of some enantiomers (1-(4-chlorophenyl) ethanol and 2-chloro-2-phenylacetophenone) reached 3.00. Compared with CTpBD@SiO2, β-CD-COF@SiO2, and two widely used commercial chiral columns (Chiralpak AD-H and Chiralcel OD-H), it was found that the fabricated column had good chiral recognition complementarity with four chiral chromatographic columns. Furthermore, the effects of the injection mass of the analyte, column temperature, and the proportion of the mobile phase on the separation of racemates were also discussed. This column exhibited good reproducibility and stability. After hundreds of injections, the relative standard deviation (RSD) values of retention time and resolution were both below 1%. In addition, the proposed CD-COF-Li@SiO2-based HPLC method demonstrated favorable performance for quantitative analysis by using (S)-ethyl mandelate as a model analyte. Accordingly, the limit of detection value of 0.38 µg·mL-1 and the limit of quantitation value of 1.26 µg·mL-1 for (S)-ethyl mandelate detection were obtained. This work highlights the promising prospects of chiral iCOFs for enantioseparation in HPLC.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Construction of core-shell silica@cationic covalent organic framework for HPLC separation.Talanta · 2026
- Versatile Dual-Chiral Covalent Organic Framework Microspheres Synthesized at Room Temperature for Chromatographic Separation and Raman Detection of Chiral Polar Compounds.Analytical chemistry · 2026
- In situ fabricated chiral-induced covalent organic frameworks interfacial coatings on capillary wall for high-efficiency enantioseparation of chiral drugs: experimental and density functional theory insights into stereoselective recognition mechanisms.Mikrochimica acta · 2026
- Bottom-up synthesis of bridged Bis(β-cyclodextrin)-functionalized chiral COFs@SiO2 for enantioseparation in liquid chromatographyJournal of Chromatography A · 2026
- Single cellulose nanocrystal rod-templated right-handed imine-linked covalent organic frameworks for enantioselective recognition.Chemical science · 2026
- Electron Donor–Acceptor Systems in Electrochemiluminescent Chiral Covalent Organic Frameworks for Enantioselective DiscriminationAdvanced Optical Materials · 2025