Capacitive Genosensor for SARS‐CoV‐2 RNA Detection
Sinan Akkurt, Yasemin Delen Akçay
Key points
From the paper's conclusion- These findings demonstrate that the proposed PPy/APBA‐based capacitive genosensor provides a rapid, sensitive, and cost‐effective platform for amplification‐free detection of SARS‐CoV‐2 RNA and represents a promising candidate for point‐of‐care compatible nucleic acid diagnostics.
Abstract
Rapid and reliable detection of SARS‐CoV‐2 RNA remains essential for effective surveillance and early diagnosis of COVID‐19 infection. In this study, a label‐free electrochemical capacitive genosensor was developed for sensitive detection of SARS‐CoV‐2 RNA using a screen‐printed carbon electrode modified with electropolymerized polypyrrole (PPy) and aminophenylboronic acid (APBA). Stable immobilization of the RNA probe was achieved through electrostatic interactions with the conductive polymer matrix and reversible boronate–ribose binding, providing improved probe stability and hybridization efficiency without the need for labeling or amplification steps. Hybridization events were monitored via chronoimpedimetric measurements based on interfacial capacitance changes at the electrode–electrolyte interface. Under optimized conditions in HEPES buffer (50 mM, pH 6.5), the developed genosensor exhibited a rapid response with an optimal hybridization time of approximately 90 s and demonstrated a linear analytical range between 10 and 1000 fM (R 2 = 0.9926 ± 0.0052, n = 5). The limit of detection and limit of quantification were calculated as 3.1 fM and 9.3 fM, respectively, comparable to previously reported amplification‐free electrochemical SARS‐CoV‐2 genosensors. Repeatability studies performed by spiking RNA into serum samples showed minimal matrix interference (~4% deviation from calibration values), with recovery values of 106.2% and 102.1% at 10 and 1000 fM, respectively, confirming satisfactory analytical accuracy. Six biosensors stored at +4 °C or at room temperature in the dark retained 96.9%/91.1% and 87.2%/78.5% of their initial response after 30 and 60 days, respectively, confirming acceptable long‐term stability, more pronounced at +4 °C. These findings demonstrate that the proposed PPy/APBA‐based capacitive genosensor provides a rapid, sensitive, and cost‐effective platform for amplification‐free detection of SARS‐CoV‐2 RNA and represents a promising candidate for point‐of‐care compatible nucleic acid diagnostics.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Novel paper-based electrochemical system for detection of anti-spike protein antibodies from SARS-CoV-2Microchimica Acta · 2026
- Capillary-Driven Duplex Microfluidic Device Enabling Simultaneous Electrochemical Immunoassays for Detecting SARS-CoV-2 and Respiratory Syncytial VirusACS Sensors · 2026
- From Bench to Bedside: Clinical Translation of Electrochemical Biosensors for Viral Diagnostics.Diagnostics (Basel, Switzerland) · 2026
- Comparative Evaluation of Rapid Nucleic Acids Extraction Methods for Biosensor-Based Point-of-Care SolutionsBiosensors · 2026
- Nonenzymatic Detection of SARS-CoV‑2 RNA Using DNA Nanoswitches.ACS nano medicine · 2026
- CRISPR/Cas12a2 enables ultra-sensitive amplification-free RNA detectionNucleic Acids Research · 2025