Multiwalled Carbon Nanotube/Carbon Paste‐Modified Graphite Sheet Electrode Using Uric Acid as a Naturally Occurring Redox‐Active Molecule for Aptamer‐Mediated Signal Transduction
Jixin Shang, Zhuoya Liao, Qianxi Zhao, Huizi Zhang, Toru Nohgi, Jun Kameoka
Key points
From the paper's conclusion- These results support UA‐mediated signal transduction in a controlled model system and show normalized responses of similar magnitude across the tested UA backgrounds.
Abstract
This study examines the use of uric acid (UA), a naturally occurring redox‐active molecule, as a reporter for aptamer‐mediated electrochemical signal transduction. Five graphite‐sheet electrode configurations were compared, with the multiwalled carbon nanotube/carbon paste‐modified graphite sheet electrode (MWCNT/CP/GSE) providing the strongest overall UA response. The measured linear UA range was 50–1000 μM, with a blank‐derived limit of detection of 0.26 μM and a calculated limit of quantification of 0.87 μM. Standard‐redox‐probe cyclic voltammetry (CV) and electrochemical impedance spectroscopy, together with a nanotube‐free CV‐treatment control, provided complementary evidence for changes caused by the modification sequence. Four consecutive UA measurements on the same MWCNT/CP/GSE electrode showed no progressive current loss, while the interdevice relative standard deviation was 9.2% across three independently fabricated electrodes. Using the T5 testosterone‐binding aptamer, the UA oxidation current decreased over the tested 100–700 nM testosterone interval. Additional cortisol, estradiol, and progesterone time‐course controls showed no comparable progressive attenuation under the tested conditions. At 400 nM testosterone, mean peak‐current retention was 78.83%–82.34% across 50, 100, and 200 μM UA backgrounds. These results support UA‐mediated signal transduction in a controlled model system and show normalized responses of similar magnitude across the tested UA backgrounds. The present study establishes a proof of concept in buffer; physiological testosterone sensitivity and quantitative performance in sweat remain to be established.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A novel tin-oxide nanoparticle-modified glassy carbon electrode for the highly selective and simultaneous detection of dopamine, uric acid, and ascorbic acidNew Journal of Chemistry · 2025
- Aptamer-Functionalized SWCNT Optical Sensors for Selective and Robust Dopamine Detection in Physiological MediaACS Applied Nano Materials · 2026
- Carbon Nanotubes Electrode Engineering for Nonenzymatic Electrochemical Biosensing: A Comparative Study of Fibrous and Powdered ArchitecturesChemistrySelect · 2026
- Label-free electrochemical aptasensor for sensitive and selective recognition of N6-Methyladenosine: Applicability in human urine.Talanta · 2026
- Application of a g-C₃ N₄ @nZVI/CNTs Modified Carbon Paste Electrode for Uric Acid Detection in Spiked Urine SamplesECS Sensors Plus · 2025
- Adsorption-controlled electrooxidation of ensartinib at a nanostructured Al2O3-MWCNT electrode: first electrochemical insights.BMC chemistry · 2026