A Single-Aliquot Strategy for Simultaneous Carbon Isotope Confirmation of 6-Oxo-Androstenedione and Testosterone Misuse in Doping Control.
Fábio Azamor de Oliveira, Cristiane Abrantes da Silva, Carolina Dos Reis Farias, Mariana Trad Rosner da Motta, Thais Reis da Silva, Natasha Veiga Louzada, Monica Costa Padilha, Henrique Marcelo Gualberto Pereira
Federal University of Rio de Janeiro-UFRJ, Brazilian Doping Control Laboratory-LBCD, LADETEC, Rio de Janeiro, Brazil.
Key points
From the paper's conclusion- Overall, the outcomes show that all WADA method validation requirements were met and that the proposed strategy for simultaneous CIR analysis of 6-oxo and testosterone markers in a single analytical workflow was successful.
Abstract
A method compliant with World Anti-Doping Agency (WADA) requirements was validated for carbon isotope ratio (CIR) analysis enabling the simultaneous confirmation of 6-oxo-androstenedione (6-oxo) metabolites and testosterone steroid profile markers from a single urine sample aliquot. The approach allows differentiation between endogenous and exogenous steroid origins when 6α-hydroxy-androst-4-ene-3,17-dione (6α-OH), a marker of misuse of 6-oxo or testosterone prohormones, is detected in athlete samples. CIR analysis is laborious and usually requires large sample volumes. Therefore, this study aimed to validate a method capable of simultaneously performing both confirmations from a single sample aliquot. Based on a previously validated method for testosterone confirmation, 6α-OH, its 6β-epimer, and 6-oxo were included and validated as markers of 6-oxo intake. The proposed method, anchored in two liquid-chromatography clean-up steps, yielded peaks of adequate purity, negligible isotopic fractionation, and amplitudes suitable for CIR steroid analysis within typical linear ranges. Limits of quantification were 5.0 ng/mL for 6α- and 6β-OH and 15 ng/mL for 6-oxo, with combined uncertainties of 0.6‰, 0.5‰ and 0.4‰, respectively. Application to authentic samples demonstrated the method's fitness for purpose in differentiating negative from positive samples. Overall, the outcomes show that all WADA method validation requirements were met and that the proposed strategy for simultaneous CIR analysis of 6-oxo and testosterone markers in a single analytical workflow was successful.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comprehensive Profiling of 6α‐Chloro‐Testosterone Metabolism in Human Urine Using Gas Chromatography–Mass SpectrometryDrug Testing and Analysis · 2026
- Analytical strategies for distinguishing endogenous and exogenous anabolic androgenic steroids in doping control.Analytical methods : advancing methods and applications · 2026
- Fragment-Resolved Carbon and Hydrogen Isotope Analysis of Urinary Steroids by Orbitrap Mass Spectrometry.Analytical chemistry · 2026
- A Putative Testosterone Precursor Helps to Overcome ABP Limitations in Doping Detection for Low Urinary Testosterone Populations.Drug testing and analysis · 2026
- Simplified Analysis of Native Steroid Esters in Dried Blood Spots by LC–MS³Journal of Mass Spectrometry · 2025
- Simultaneous Detection of Steroid Esters and Multi-Class Substances in Dried Blood Spots by LC-HRMS/MS From a Single Spot for Human Doping Control.Drug testing and analysis · 2026