Environmental Impact of Conventional Versus Underwater Endoscopic Mucosal Resection for Colorectal Lesions: A Procedure‐Based Life Cycle Assessment With Pooled Effectiveness Estimates
Giulio Calabrese, Frederic Moll, João A. Cunha Neves, Livio Bonacci, Emanuele Sinagra, Fabiana Castiglione, Marcello Maida, Eduardo Albéniz‐Arbizu,
Key points
From the paper's conclusion- We compared procedure‐related environmental outcomes between conventional endoscopic mucosal resection (EMR) and underwater EMR (U‐EMR) for colorectal lesions.
Abstract
Objectives The environmental impact of endoscopic techniques remains poorly defined. We compared procedure‐related environmental outcomes between conventional endoscopic mucosal resection (EMR) and underwater EMR (U‐EMR) for colorectal lesions. Methods In this prospective pilot procedure‐based life cycle assessment of the resection phase, 10–25‐mm colorectal lesions underwent EMR or U‐EMR across three endoscopy units. Outcomes included global warming potential (GWP, kg CO 2 ‐equivalent/procedure), waste, life‐cycle water consumption, fossil resource scarcity, and terrestrial acidification. Exploratory GWP per en bloc resection was estimated using pooled randomized‐trial and pilot‐cohort data. Results Forty‐nine procedures were included: 23 EMR and 26 U‐EMR. En bloc resection was achieved in 56.5% of EMR and 69.2% of U‐EMR, and R0 resection in 52.2% and 69.2%. Mean GWP was significantly lower with U‐EMR than EMR (1.92 ± 0.54 vs. 2.42 ± 0.50 kg CO 2 ‐eq; p = 0.002), corresponding to a reduction of 0.50 kg CO 2 ‐eq per procedure and 50 kg CO 2 ‐eq per 100 procedures. U‐EMR was associated with lower waste generation (324.0 ± 78.3 vs. 407.3 ± 72.0 g; p < 0.001), water consumption (0.56 ± 0.17 vs. 0.77 ± 0.20 m 3 ; p < 0.001), fossil resource scarcity (0.33 ± 0.10 vs. 0.40 ± 0.09 kg oil‐eq; p = 0.007), and terrestrial acidification (0.0052 ± 0.0018 vs. 0.0068 ± 0.0018 kg SO 2 ‐eq; p = 0.003). Findings were consistent across scenario and uncertainty analyses. In the meta‐analysis‐based model, GWP per en bloc resection was lower with U‐EMR than EMR (2.59 vs. 3.51 kg CO 2 ‐eq), corresponding to a 26.3% relative reduction. Conclusions U‐EMR was associated with lower procedure‐related environmental burden than conventional EMR, persisting after normalization for en bloc resection. Trial Registration No. 165/26
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Quantification of Medical Waste and Incineration‐Related CO 2 Emissions Associated With Gastrointestinal Endoscopy at Two Facilities in Japan: A Preliminary Observational StudyDEN Open · 2026
- Underwater Endoscopic Mucosal Resection for Serrated Lesions: A Systematic Review and Single‐Arm Meta‐AnalysisDEN Open · 2026
- Underwater versus conventional polypectomy for colorectal polyps 10 mm or smaller: a systematic review and meta-analysis of randomized controlled trials.European journal of gastroenterology & hepatology · 2026
- Clinical Outcomes of Partial Injection Underwater Endoscopic Mucosal Resection for Superficial Non‐ampullary Duodenal Epithelial Tumors (With Video)DEN Open · 2026
- Short- and Long-Term Outcomes of Underwater Versus Conventional Colorectal Endoscopic Submucosal Dissection: A Large Retrospective Real-World Cohort Study.Endoscopy · 2026
- Underwater Endoscopic Mucosal Resection Is a Technique with a Short Learning Curve: A Multicentric Prospective Study.GE Portuguese journal of gastroenterology · 2026