The Yokohama System for Breast Cytology in Japan: A Multicenter Comparison of the International Academy of Cytology Yokohama System and the Conventional Japanese System for Reporting Breast Fine-Needle Aspiration Biopsy.
Akiyoshi Hoshino, Ichiro Maeda, Rieko Nishimura, Eiji Abe, Yuji Kozuka, Shinobu Masuda, Yasuyo Ohi, Takashi Sakatani,
Department of Pathology, Kitasato University Kitasato Institute Hospital, Minato Ward, Tokyo, Japan. · Department of Pathology, Nagoya Medical Center, Nagoya, Aichi, Japan.
Key points
From the paper's conclusion- IAC-YS showed a higher proportion of cases of Category 1 and a lower proportion of cases of Category 3 than the CJS. Despite these differences, both systems were equivalent in their impact on daily medical care, although ROM differed for the content of Categories 1 and 3. Quality assurance parameters for our data based on IAC-YS are comparable to those of CJS.
Abstract
BACKGROUND: The International Academy of Cytology (IAC) recently introduced the Yokohama System (IAC-YS) for reporting breast fine-needle aspiration biopsy (FNAB) cytology. The Working Group on the Accuracy of Breast Fine-Needle Aspiration Cytology of the Japanese Society of Clinical Cytology aimed to categorize breast FNAB specimens according to the IAC-YS, assess the risk of malignancy (ROM) for each category, and evaluate the diagnostic yield of breast FNAB in Japan. METHODS: Breast FNAB specimens obtained between January 2010 and December 2019 from nine cooperating facilities were retrospectively reclassified following the IAC-YS. The ROM for each category was calculated and compared with that using the conventional Japanese diagnostic system (CJS). Diagnostic yield was evaluated using a five-category approach to distinguish benign from malignant samples. RESULTS: In total, 1727 samples from 1722 patients were distributed as follows: Category 1 (insufficient material), 21.3%; Category 2 (benign), 38.9%; Category 3 (atypical), 6.9%; Category 4 (suspicious for malignancy), 10.0%; and Category 5 (malignant), 23.0%. Histological follow-up was available for 856 cases (49.5%). The ROM was 13.1%, 4.8%, 26.9%, 84.3%, and 94.5% for Categories 1-5, respectively. CONCLUSIONS: IAC-YS showed a higher proportion of cases of Category 1 and a lower proportion of cases of Category 3 than the CJS. Despite these differences, both systems were equivalent in their impact on daily medical care, although ROM differed for the content of Categories 1 and 3. Quality assurance parameters for our data based on IAC-YS are comparable to those of CJS.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Validation of the International Academy of Cytology Yokohama System for Reporting Breast Fine-Needle Aspiration Cytopathology.Cureus · 2026
- Diagnostic Performance of the International Academy of Cytology Yokohama System for Reporting Breast Fine-Needle Aspirates: A Cytology-Histopathology Correlation Study From Central India.Cureus · 2026
- Grey Zone Lesions in Breast Cytology Using the Yokohama System Cytohistological Correlation and Risk of Malignancy.Diagnostic cytopathology · 2026
- Cytological Grading of Palpable Breast Lesions: Comparative Analysis of Masood, Modified Masood, and Yokohama system with Cytohistological Correlation at a Newly Established Tertiary Care Center in South India.Journal of cytology · 2026
- Diagnostic Accuracy of Fine-Needle Aspiration Cytology Alone and With Cell Block Preparation for Palpable Breast Lesions: A Prospective Study in Central India.Cureus · 2026
- Clinical Applicability of the WHO Reporting System for Axillary Lymph Node Fine-Needle Aspiration in Invasive Breast Carcinoma.Cancers · 2026