Imaging for anti-amyloid therapy eligibility: Comparing GRE and SWI in detecting microhemorrhages and superficial siderosis.
Jeremy N Ford, Suely Fazio Ferraciolli, Odette Ganem Chagui, Marvin Relerford Iii, Esteban Calle Cadavid, John Dickson, Maryam Vejdani-Jahromi, Matthew N DeSalvo,
Department of Radiology Massachusetts General Hospital and Harvard Medical School Boston Massachusetts USA. · Tufts University School of Medicine Boston Massachusetts USA.
Key points
From the paper's conclusion- SWI detected more microhemorrhages than GRE (mean 1.24 vs. 0.67, p < 0.0001), identified eight additional SS cases, and showed higher interobserver agreement (ICC 0.951 vs. 0.764, p < 0.01). SWI classified more patients as MRI ineligible than GRE (26/204 [12.7%] vs. 11/204 [5.4%]).
Abstract
INTRODUCTION: Anti-amyloid therapies such as lecanemab require magnetic resonance imaging (MRI) screening to exclude patients with > 4 gradient-recalled echo (GRE)-detected microhemorrhages or any superficial siderosis (SS). Although GRE and susceptibility-weighted imaging (SWI) are both accepted, they differ in detection performance. METHODS: We retrospectively analyzed 224 eligibility MRIs with paired GRE and SWI from a single academic health system. Six neuroradiologists assessed a 20-scan reliability subset; the remaining 204 scans were assigned to one rater for hemorrhagic lesion detection and MRI-based eligibility classification. Interobserver reliability was calculated using intraclass correlation coefficients (ICCs), and sequence differences were evaluated using non-parametric tests. RESULTS: SWI detected more microhemorrhages than GRE (mean 1.24 vs. 0.67, p < 0.0001), identified eight additional SS cases, and showed higher interobserver agreement (ICC 0.951 vs. 0.764, p < 0.01). SWI classified more patients as MRI ineligible than GRE (26/204 [12.7%] vs. 11/204 [5.4%]). DISCUSSION: SWI identifies more exclusionary hemorrhagic findings and demonstrates greater reproducibility than GRE.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Differences in anti-amyloid therapy eligibility assessment based on use of the SWI versus GRE sequence.Alzheimer's & dementia (Amsterdam, Netherlands) · 2026
- SWI versus T2*GRE for ARIA-H monitoring: a pragmatic perspective on adoption in clinical practice.Neuroradiology · 2026
- ESR Essentials: susceptibility-weighted imaging-practice recommendations by the European Society for Magnetic Resonance in Medicine and Biology.European radiology · 2026
- A geometric-to-neural cascade for cerebral microbleed detection in susceptibility-weighted MRI.bioRxiv : the preprint server for biology · 2026
- Real-World Challenges in the MRI Detection and Classification of Amyloid-Related Imaging Abnormalities.AJR. American journal of roentgenology · 2026
- Cerebral microbleed assessment on MRI in a memory clinic: Reliability, prevalence, and implications for anti-amyloid therapy.Alzheimer's & dementia (Amsterdam, Netherlands) · 2026