Adaptive ZVS Control and ZCD Delay Compensation for a Single‐Phase CRM Totem‐Pole PFC Converter
Guidong Zhang, Kaikai Yang, Haiqing Li
Key points
From the paper's conclusion- Simulation and experimental results on a 1.6‐kW GaN‐based prototype demonstrate that the proposed method achieves reliable ZVS over the investigated operating range, effectively limits the switching frequency under light‐load conditions, and mitigates the input‐current distortion caused by the ZCD delay.
Abstract
This paper presents an adaptive zero‐voltage‐switching (ZVS) control and zero‐current‐detection (ZCD) delay compensation strategy for a single‐phase critical‐conduction‐mode (CRM) totem‐pole power‐factor‐correction (PFC) converter. Conventional CRM and quasi‐square‐wave (QSW) control schemes suffer from three inherent limitations: ZVS failure in the high‐input‐voltage region, excessive switching‐frequency rise under light‐load conditions, and input‐current distortion caused by the fixed ZCD propagation delay. To address these issues, a state‐plane‐based model is first established to derive the ZVS condition and its failure boundary. Based on this model, an online timing scheme is developed that incorporates the minimum ZVS time‐margin requirement and the maximum switching‐frequency limit, and adaptive dynamic dead times are introduced to accommodate resonant transitions under varying operating conditions. In addition, a ZCD delay compensation method combining zero‐crossing blocking and full‐line‐cycle feedforward correction is proposed to suppress reverse current and improve input‐current waveform quality. Simulation and experimental results on a 1.6‐kW GaN‐based prototype demonstrate that the proposed method achieves reliable ZVS over the investigated operating range, effectively limits the switching frequency under light‐load conditions, and mitigates the input‐current distortion caused by the ZCD delay.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Asymmetric T‐Type PFC Converter With Sensorless Current Control Strategies Based on Different Pulse Width Modulation TechniquesInternational Journal of Circuit Theory and Applications · 2026
- A ZVT-PWM Boost Converter With an Auxiliary Resonant Circuit and Adaptive Dead-Time Control for Conducted EMI MitigationEngineering Research Express · 2026
- Seamless Dual Mode Control Strategy for Wide Soft Switching Range in Consumer-Centric Dual Active Bridge ConvertersIEEE Transactions on Consumer Electronics · 2026
- A Two-Phase High-Step-Down DC-DC Converter with Zero-Voltage Switching and Automatic Current SharingElectronics · 2026
- Boundary-Current-Mode Control for Single-Phase Microinverters: ZVS Operation, Modulation Strategies, and Reset-Current TradeoffsElectronics · 2026
- A Decoupled Phase-Shift-Compensation ZVS Modulation Method for Three-Phase AC–DC DAB Converters With High-Frequency-Coupling StructureIEEE Transactions on Power Electronics · 2026