Clinical cardiology

Diagnostic Performance of a Deep Learning Model Using Phonocardiogram and Single-Lead ECG Signals for Detecting Moderate-or-Greater Aortic Stenosis: Multicenter External Validation.

Shumpei Saito, Masanobu Ishii, Shimpei Ogawa, Hiroshi Seki, Koshiro Ikeda, Youhei Kayano, Yuhei Yasui, Ginga Sato,

AMI Inc, Kagoshima, Japan. · Department of Medical Information Science, Graduate School of Medical Sciences, Kumamoto University, Kumamoto, Japan.

Computational · n=951

Key points

From the paper's conclusion
  • The eAS model demonstrated high diagnostic performance for detecting moderate-or-greater AS in a multicenter external validation cohort. AI-based PCG/ECG analysis may support the decision to refer patients from auscultation to echocardiography for AS evaluation.

Abstract

BACKGROUND: Valvular heart disease, particularly aortic stenosis (AS), often remains asymptomatic until advanced stages, making early detection challenging. Although cardiac auscultation is a traditional screening tool, its diagnostic accuracy is limited. We aimed to externally validate a deep learning-based model (eAS model) using phonocardiogram (PCG) and single-lead electrocardiogram (ECG) signals to detect moderate-or-greater AS. METHODS: PCG and ECG recordings were acquired using a PCG device (Cardio-EGG). Transthoracic echocardiography served as the reference standard. The external validation cohort consisted of 951 patients from 3 medical institutions, including 70 with moderate-or-greater AS. The primary outcome was sensitivity for detecting moderate-or-greater AS; secondary outcomes included the area under the receiver operating characteristic curve (AUROC), specificity, predictive values, and likelihood ratios (LR). RESULTS: The external validation cohort (n = 951, median age 73 years, male 65%) exhibited more advanced valvular disease than the training/development cohort. The eAS model achieved an AUROC of 0.9632 (95% CI: 0.9471-0.9774). Using the pre-determined threshold, sensitivity was 92.9% and specificity 87.9%, yielding a positive LR of 7.65 and negative LR of 0.08. Model-derived probabilities showed strong associations with echocardiographic measures of AS severity (adjusted R2 = 0.5051 for peak transvalvular velocity). Exploratory subgroup analyses showed generally consistent performance, although estimates were imprecise in small subgroups. CONCLUSION: The eAS model demonstrated high diagnostic performance for detecting moderate-or-greater AS in a multicenter external validation cohort. AI-based PCG/ECG analysis may support the decision to refer patients from auscultation to echocardiography for AS evaluation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Diagnostic Performance of a Deep Learning Model Using Phonocardiogram and Single-Lead ECG Signals for Detecting Moderate-or-Greater Aortic Stenosis: Multicenter External Validation — Science Skim