Diagnostic Performance of a Deep Learning Model Using Phonocardiogram and Single-Lead ECG Signals for Detecting Moderate-or-Greater Aortic Stenosis: Multicenter External Validation.
Shumpei Saito, Masanobu Ishii, Shimpei Ogawa, Hiroshi Seki, Koshiro Ikeda, Youhei Kayano, Yuhei Yasui, Ginga Sato,
AMI Inc, Kagoshima, Japan. · Department of Medical Information Science, Graduate School of Medical Sciences, Kumamoto University, Kumamoto, Japan.
Key points
From the paper's conclusion- The eAS model demonstrated high diagnostic performance for detecting moderate-or-greater AS in a multicenter external validation cohort. AI-based PCG/ECG analysis may support the decision to refer patients from auscultation to echocardiography for AS evaluation.
Abstract
BACKGROUND: Valvular heart disease, particularly aortic stenosis (AS), often remains asymptomatic until advanced stages, making early detection challenging. Although cardiac auscultation is a traditional screening tool, its diagnostic accuracy is limited. We aimed to externally validate a deep learning-based model (eAS model) using phonocardiogram (PCG) and single-lead electrocardiogram (ECG) signals to detect moderate-or-greater AS. METHODS: PCG and ECG recordings were acquired using a PCG device (Cardio-EGG). Transthoracic echocardiography served as the reference standard. The external validation cohort consisted of 951 patients from 3 medical institutions, including 70 with moderate-or-greater AS. The primary outcome was sensitivity for detecting moderate-or-greater AS; secondary outcomes included the area under the receiver operating characteristic curve (AUROC), specificity, predictive values, and likelihood ratios (LR). RESULTS: The external validation cohort (n = 951, median age 73 years, male 65%) exhibited more advanced valvular disease than the training/development cohort. The eAS model achieved an AUROC of 0.9632 (95% CI: 0.9471-0.9774). Using the pre-determined threshold, sensitivity was 92.9% and specificity 87.9%, yielding a positive LR of 7.65 and negative LR of 0.08. Model-derived probabilities showed strong associations with echocardiographic measures of AS severity (adjusted R2 = 0.5051 for peak transvalvular velocity). Exploratory subgroup analyses showed generally consistent performance, although estimates were imprecise in small subgroups. CONCLUSION: The eAS model demonstrated high diagnostic performance for detecting moderate-or-greater AS in a multicenter external validation cohort. AI-based PCG/ECG analysis may support the decision to refer patients from auscultation to echocardiography for AS evaluation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Aortic Valve Stenosis Screening Using Deep Learning on Noninvasive Arterial Pressure Waveforms.JACC. Advances · 2026
- A screening method for aortic valve disease based on spectral analysis of a single-channel electrocardiogram using machine learning algorithms.Frontiers in cardiovascular medicine · 2026
- Multimodal deep learning model for enhanced early detection of aortic stenosis integrating ECG and chest x-ray with cooperative learningFrontiers in Radiology · 2025
- Integrating Deep PPG Representations and Digital Biomarkers for Aortic Stenosis Detection with Peri-TAVI AssessmentarXiv · 2026
- Development and External Validation of an Echocardiography-Based AI Model for Predicting Aortic Stenosis Progression.JACC. Advances · 2026
- Comprehensive Aortic Stenosis Characterization Using Multiview Deep Learning.JACC. Cardiovascular imaging · 2026