The Canadian Journal of Chemical Engineering

Ultrasound velocity profiling of wood chips flow in an industrial application

Sofia Evysdotter, Tomas Vikström, Anders Rasmuson

Key points

From the paper's conclusion
  • The velocity profiles of the wood chips show a non‐zero velocity at the wall, a sharp gradient (a shear zone), and a plug flow, indicating that it is reasonable to assume that wood chips behave as a dense granular flow on industrial scale.

Abstract

Ultrasound velocity profiling (UVP) was applied to an industrial impregnation vessel containing wood chips and liquid. The method could successfully determine the velocity of the wood chips by measuring through the 15 mm thick steel wall. The measuring depth is and covers 8% of the radius. Even though the measuring depth is limited this method is able to capture the normal production variations of the mill. The velocity profiles of the wood chips show a non‐zero velocity at the wall, a sharp gradient (a shear zone), and a plug flow, indicating that it is reasonable to assume that wood chips behave as a dense granular flow on industrial scale.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Ultrasound velocity profiling of wood chips flow in an industrial application — Science Skim