Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions

Structural Damage of Coronary Microcatheters During Chronic Total Occlusion Percutaneous Coronary Interventions: The Prospective Multicenter Cross Registry.

Ignacio J Amat-Santos, Filippo Pensotti, Giorgio Marengo, Gemma Miñana, Javier Martin Moreiras, Claudiu Ungureanu, Ander Regueiro, Tiago Pereira da Silva,

Cardiology Department, University Clinic Hospital of Valladolid, Valladolid, Spain. · Cardiology Department, Azienda Ospedaliera, Città della Salute e della Scienza di Torino, Turin, Italy.

Observational

Key points

From the paper's conclusion
  • Structural microcatheter damage occurred in approximately 1 in 20 CTO PCIs and was associated with anatomical complexity, demanding procedural circumstances, and substantially worse procedural outcomes.

Abstract

BACKGROUND: Coronary microcatheters are essential in chronic total occlusion (CTO) percutaneous coronary intervention (PCI), but their structural failure has mainly been described through passive surveillance. AIMS: We aimed to determine the incidence, predictors, and procedural impact of microcatheter structural damage during contemporary CTO PCI. METHODS: The prospective multicentre CROSS registry included 2137 CTO PCI procedures performed at high-volume centers between 2024 and 2025. Suspected damaged microcatheters underwent centralized assessment and were classified as grade 1 (superficial deformation), grade 2 (significant deformation without complete fracture), or grade 3 (complete fracture). RESULTS: Structural damage occurred in 109 procedures (5.1%); 58.7%, 5.5%, and 35.8% were grade 1, 2, and 3, respectively. Independent predictors of structural microcatheter damage were moderate-to-severe calcification (adjusted OR, 1.93; 95% CI, 1.27-2.94), retrograde approach (adjusted OR, 1.71; 95% CI, 1.10-2.67), moderate-to-severe tortuosity (adjusted OR, 1.61; 95% CI, 1.04-2.50), and longer procedure duration (adjusted OR per 30-min increase, 1.17; 95% CI, 1.06-1.30). Structural damage was associated with increased periprocedural complications (25.7% vs. 7.7%; OR: 4.12, 95% CI: 2.60-6.52; p < 0.0001) and failed CTO PCI (11.0% vs. 3.1%; OR: 3.86, 95% CI: 2.01-7.39; p < 0.0001). CONCLUSIONS: Structural microcatheter damage occurred in approximately 1 in 20 CTO PCIs and was associated with anatomical complexity, demanding procedural circumstances, and substantially worse procedural outcomes.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Structural Damage of Coronary Microcatheters During Chronic Total Occlusion Percutaneous Coronary Interventions: The Prospective Multicenter Cross Registry — Science Skim