Catheter-Directed Interventional Devices for Pulmonary Embolism: A Maude Database Analysis of Adverse Events.
Shreyas Nandyal, Rohan Gajjar, Revati Varma, Saketh Vinjamuri, Krishna Saketh Athmakuri, Aviral Vij
John H. Stroger Jr. Hospital of Cook County, Chicago, Illinois, USA. · Cleveland Clinic Fairview Hospital, Ohio, USA.
Key points
From the paper's conclusion- Aims To characterize adverse events, device failure patterns, and mortality signals for three FDA‐cleared catheter‐directed PE platforms (EKOSONIC, INDIGO, and FlowTriever) using the FDA Manufacturer and User Facility Device Experience (MAUDE) database.
Abstract
BACKGROUND: Catheter-directed therapies for acute pulmonary embolism (PE) are being adopted rapidly, yet real-world safety data remain limited. AIMS: To characterize adverse events, device failure patterns, and mortality signals for three FDA-cleared catheter-directed PE platforms (EKOSONIC, INDIGO, and FlowTriever) using the FDA Manufacturer and User Facility Device Experience (MAUDE) database. METHODS: Medical device reports (MDRs) were downloaded from each device's PE clearance (2008, 2015, and 2018, respectively) through March 2026 and filtered by text to retain PE-specific reports. Reports were classified by manufacturer, event type (death, injury, malfunction), device problem, and patient problem, and trends were assessed by calendar year. RESULTS: Of 2528 reports, 389 were PE-specific (INDIGO 228 [58.6%], EKOSONIC 149 [38.3%], FlowTriever 12 [3.1%]), spanning 2009 to January 2026. There were 76 deaths (19.5%), 133 injuries (34.2%), and 180 malfunctions (46.3%). Annual death reports rose from 2023 (15 in 2023, 13 in 2024, 8 in 2025, and 3 in January 2026). Among 47 INDIGO deaths, 28 (59.6%) involved Lightning/Flash large-bore catheters, and 36 (76.6%) carried a perforation-, hemoptysis-, tamponade-, or extravasation-related patient problem code. Separator wire break/fracture was the leading INDIGO device failure. EKOSONIC reports showed thrombolytic-related bleeding, including intracranial or cerebral hemorrhage in 12 reports (8.1%). CONCLUSIONS: MAUDE reports reveal distinct device-specific safety signals: pulmonary artery perforation with large-bore INDIGO aspiration catheters, and intracranial hemorrhage with EKOSONIC. Death reports increased from 2023 as mechanical thrombectomy use expanded. Absent procedural denominators, rates and causality cannot be inferred; findings support operator awareness, careful patient selection, and continued post-market surveillance.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Trends in catheter-directed therapy and in-hospital outcomes among patients with acute pulmonary embolism: insights from a multicentre national quality assurance database registryEuropean Heart Journal Acute Cardiovascular Care · 2025
- Adverse Event Landscape of Pulsed Field Ablation Catheters: A Computational Review of FDA MAUDE Post-Market Surveillance Data.Reviews in cardiovascular medicine · 2026
- Reported adverse event with the TriClip device for tricuspid Transcatheter edge-to-edge repair: Analysis of the MAUDE database.Cardiovascular revascularization medicine : including molecular interventions · 2026
- Post-market individual-report phenotypes after pulsed-field ablation for atrial fibrillation in a food and drug administration database.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2026
- Mechanical Thrombectomy and Catheter-Directed Thrombolysis in Acute Pulmonary Embolism: Trends and Practice Patterns in the PERT Consortium Registry (2016-2024).Journal of the American College of Cardiology · 2026
- Transcatheter Directed Interventions in Pulmonary Embolism: Recent Evidence, Guidelines and Challenges.Journal of cardiovascular development and disease · 2026