Mahsa Shahsavan, Cedrik Wiberg, Andrea Hamza, Aapo Poskela, Johan Hjelm, Pekka Peljo
The performance of the negatively charged aspartic acid‐functionalized naphthalene diimide (ASP‐NDI) in a flow battery is investigated in this article. The high concentration ASP‐NDI/ferrocyanide flow battery presented cycled for 79.8 days with an average coulombic efficiency of 99.9% and an energy efficiency of 87.5% at 20 mA cm −2 while accessing an over 90% of the theoretical capacity of ASP‐NDI with a capacity fade rate of 0.0275% per day that is the lowest reported for the NDI‐based flow batteries to date.