Efficiency assessment of façade fire separation distances against the leap‐frog effect
Krisztián Sándor Oláh, Lajos Gábor Takács
Key points
From the paper's conclusion- Across European countries, different separation distances from 0.6 m to 1.3 m are used to protect façades with openings against leap‐frog fire spread.
Abstract
Across European countries, different separation distances from 0.6 m to 1.3 m are used to protect façades with openings against leap‐frog fire spread. The aim of all of these separation distances is to delay the fire propagation through adjacent façade openings. According to the literature, the estimated duration of this fire spread process, including the development of the enclosure fire, is about 15 min to 45 min. Based on the earlier full‐scale fire tests dedicated to determining the appropriate separation distance, the efficiency, or in other words, the delay of the fire spread caused by the separation itself cannot be determined precisely. With the numerical modelling of the externally venting flame according to the MSZ 14800‐6 standard, we have an opportunity to measure this delay more precisely and even compare the efficiency of the different separation distances. In this paper, three different internationally used separation distances were compared based on two representative aspects of the phenomenon to clarify the significance and efficiency of separation distances in the current fire safety regulations. Based on the results, the biggest separation distance evidently reduced the risk of leap‐frog fire spread. However, the differences did not seem critical.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Fire Spread Characteristics of Cavities in Modular Constructions and Ventilated FacadesFire and Materials · 2026
- Data-Driven Selection of Parametric and Travelling Fire Models for Performance-based Fire Design.Fire technology · 2026
- Fire Smoke Transport in Inclined Evacuation Passages of Deep-Buried Metro Stations: A Reduced-Scale Experimental StudyFire · 2026
- Wind-Driven Building-to-Building Fire Spread: Experimental Results and Probabilistic ModelingFire Technology · 2026
- Convective-Buoyancy Scaling and Thermal Attenuation of Two-Stage Smoke Propagation in an Open-Door Metro Carriage–Tunnel FireFire · 2026
- Decision-Level Uncertainty Calibration for Fire-Tenability Surrogates: Effects on ASET and Evacuation Failure ProbabilityFire · 2026