Arthroscopy, sports medicine, and rehabilitation

Knotless Suture Anchors Reduce Repair Time in Arthroscopic Hip Labral Repair Compared With Knotted Anchors.

Ady H Kahana-Rojkind, Tyler McCarroll, Roger Quesada-Jimenez, Absolon Reyes-Cordova, Dean Sandler, Etan P Sugarman, Benjamin G Domb

American Hip Institute Research Foundation Chicago Illinois U.S.A.

Key points

From the paper's conclusion
  • Conclusions Knotless suture anchors significantly reduced acetabular labral repair time compared with knotted anchors in this cadaveric model, primarily because of a shorter Tie/Convert phase required for suture fixation.

Abstract

PURPOSE: To compare procedure time between knotless and knotted all-suture anchors during arthroscopic acetabular labral repair in a cadaveric model and to evaluate implications for surgical training and workflow efficiency. METHODS: Ten fresh-frozen cadaveric hemipelvis specimens underwent arthroscopic labral repair. Five specimens (20 anchors) were repaired using knotted all-suture anchors, and 5 specimens (20 anchors) were repaired using tensionable knotless all-suture anchors. A standardized simple-loop suture configuration was used in all repairs. Repair time per anchor was recorded and subdivided into "Pass," "Tie/Convert," and "Cut" phases. Comparisons between groups were performed using independent t tests or Mann-Whitney U tests, with α = 0.05. RESULTS: Mean total repair time per anchor was significantly shorter in the knotless group (79.36 ± 18.07 seconds) compared with the knotted group (142.48 ± 27.96 seconds; P = .007). Tie/Convert phase was also significantly shorter in the knotless group (15.92 ± 4.50 seconds vs 73.11 ± 18.44 seconds; P < .001). Pass phase was slightly longer with knotless anchors (52.94 ± 24.92 seconds vs 43.41 ± 23.83 seconds; P = .050). Cut phase was shorter with knotless anchors (11.35 ± 4.93 seconds vs 25.70 ± 27.06 seconds; P = .191) although not statistically significant. CONCLUSIONS: Knotless suture anchors significantly reduced acetabular labral repair time compared with knotted anchors in this cadaveric model, primarily because of a shorter Tie/Convert phase required for suture fixation. CLINICAL RELEVANCE: Knotless suture anchors may streamline labral repair by eliminating arthroscopic knot tying. Their technical simplicity and efficiency may benefit surgical training and enhance consistency among less experienced surgeons.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Knotless Suture Anchors Reduce Repair Time in Arthroscopic Hip Labral Repair Compared With Knotted Anchors — Science Skim