Electric Arc Detection System Using the Random Forest Method on Electric Train Trolley Wires
Ahmad Sugiana, Heru Syah Putra, Wichai Siwakosit
Key points
From the paper's conclusion- The results show that the level of accuracy in random forest reaches 99.50%, in addition, experiments were also carried out in the dynamic laboratory conditions, the system produced an accuracy of 95.60% so that these results can be trusted where the method used is not a perfect solution but to overcome the problem by combining the type of spark into an early warning for the system.
Abstract
Trains are a widely used transportation method for Indonesian people, with the use of overhead electricity as one of the highlights. This study focuses on sparks from overhead electricity, which can cause, that often occurs, a problem that is the focus of this study, because sparks from overhead electricity can cause various safety risks for very sensitive train. Therefore, early detection is very necessary considering that safety is the main concern of transportation. The development of a machine learning‐based system as an alternative is proposed for this problem. The use of various sensors that are relatively inexpensive on a small scale, such as ESP32 as a media device for data processing and PZEM‐017 sensors, can collect electricity data in real‐time. The dataset consists of 8000 samples (2000 samples per class) covering four operational conditions: no contact, normal, constant arc, and arc initiation. From these concerns, accurate output is obtained by calculating the average and standard deviation to see the results of the system used. In experiments with various configurations, each algorithm, such as Random Forest and SVM, has performed differently. Random forests show significant test results that outperform other methods. The results show that the level of accuracy in random forest reaches 99.50%, in addition, experiments were also carried out in the dynamic laboratory conditions, the system produced an accuracy of 95.60% so that these results can be trusted where the method used is not a perfect solution but to overcome the problem by combining the type of spark into an early warning for the system. This is distinct from the 99.56% average cross‐validation score obtained during hyperparameter tuning. In the future, this system will be tested in the railway area with the same method so that it can be used as a reference for implementation on trains.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Machine Learning Approaches for Residential Electrical Fire Risk Assessment: A ReviewABUAD Journal of Engineering Research and Development (AJERD) · 2026
- A Hybrid Two-Stage Machine Learning Pipeline for Fault Detection and Classification in Power Transmission SystemsarXiv · 2026
- Exploratory Cross-System Recognition of Candidate Pantograph Arc Intervals in DC RailwaysInfrastructures · 2026
- Machine Learning for Early Transformer Insulation Defect Risk RankingEnergies · 2026
- Arc-Fault Detection Using Stage-Wise Alignment and Feature Fusion of Dual Learnable Time-Frequency Representations.Sensors (Basel, Switzerland) · 2026
- Hybrid CNN-decision tree framework for efficient transmission line fault detection and classification: an XAI-based approachScientific Reports · 2026